InspectAPedia TM

Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice
InspectAPedia
Home
| Air
Conditioning
| Electrical | Environment | Exteriors | Heating | Home
Inspection
| Insulate
Ventilate
| Interiors | Mold
Inspect/Test
| Plumbing
Water
Septic
| Roofing | Structure | Contact Us
New Directory of Professionals to Inspect or Test a Building New


AIR CONDITIONING SYSTEMS
A/C COMPONENTS
CONTROLS & SWITCHES
A/C DATA TAGS
A/C TYPES, ENERGY SOURCES
RATED COOLING CAPACITY
AIR CONDITIONER BTU CHART
SEER RATINGS
OPERATING COST
SYSTEM OPERATION
OPERATING TEMPERATURES
OPERATING DEFECTS
LOST COOLING CAPACITY
COMPRESSOR CONDENSER
AIR HANDLER UNIT
AIR FILTERS for HVAC SYSTEMS
CONDENSATE HANDLING
CLEANING & Legionella BACTERIA
DUCT SYSTEM DEFECTS
A/C REFRIGERANTS
A/C DIAGNOSTIC FAQs
INSPECTION LIMITATIONS
CRITICAL DEFECTS
Air Conditioning "How To" Books

More Information



InspectAPedia TM Home & Site Map
AIR CONDITIONING
InspectAPedia Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Bias Pledge
Contact Us



Photograph of older side-vent combination hot air furnace and central air conditioning system. The evaporator coil or A-coil is
visible in the top of the unit. What You Should Know about Refrigerants When Purchasing or Repairing a Residential A/C System or Heat Pump
AirCondAPedia ©

Google
 
  • Consumer Information about A/C Refrigerants
  • R22 refrigerant phase-out schedule
  • Alternatives to R22 refrigerant
Our site offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at inspect-ny.com/appointment.htm.

Air conditioning refrigerants and agents to transfer heat from one place to another have been in use for a long time and include Ammonia, Sulfur Dioxide, Hydrocarbons like methane, methyl chloride, and methylene chloride, and safer (inert gas) HFCs like R11 (common in older refrigerators and some air conditioners) and R22 (common in older cooling equipment. Since the realization that HFC's contribute to greenhouse gas problems in the environment, R11 and R22 have been discontinued and are being replaced with alternatives including R-410A (GENETRON AZ-20, SUVA 410A, and Puron), R-134A R-407C.

Properties of Various Air Condition and Cooling Refrigerants

  • Ammonia is the oldest-known refrigerant. (Ammonia can generate cooling by simple mechanical movement). Ammonia vapor can be flammable, explosive, and toxic. Ammonia is lighter than air (so less likley to accumulate at a dangerous level near the floor).
  • Sulphur dioxide SO2 is obsolete and would be unusual to encounter except in very old cooling equipment. SO2 is not flammable nor explosive but with moisture is very corrosive and can injure plants.
  • Hydrocarbons such as methane CH4, isobutane C4H10, and propane C3H8 are often used as fuels and solde as bottled gas. Methyl chloride CH3CL has also been used as has methylene chloride CH2CL2. These halogenated hydrocarbons are less flammable; Carrene No.1 was a popular trade product version of methylene chloride (the safest of these).
  • Freon & Genetron: Chemists also tried using carbon tetrachloride CCL4 as a refrigerant by adding two chlorine atoms to produce CCL2F2 which founded the "R" refrigerant family R11 and R22. These HCFC or "CFC" refrigerants were very safe (non combustible, non-toxic to humans except as an oxygen displacer) and were the most widely used until their effects in the atmosphere were understood as a serious environmental problem. The 1987 Montreal Protocol which banned their use is discussed below.
  • Modern refrigerants replacing the "R" series include R-410A (GENETRON AZ-20, SUVA 410A, and Puron), R-134A R-407C. These new gases have wide use. For example, the refrigerant gas R-134A is used in medications such as propellant in bronchiodialators for asthmatics like Xopenex HFA (TM).
  • Water was used and continues to be used to effect heat transfers in cooling tower type air conditioning systems and in "swamp coolers" which work effectively where ambient humidity is low enough to produce a good evaporation rate, such as in the American southwest. (Concerns for bacterial hazards such as Legionella occur in these systems and are discussed at CLEANING A/C EQUIPMENT
© Copyright 2008 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use the links at page left to navigate this document or to go to Other Website Topics. Green links at left show where you are in our document & website.

DISCLAIMER: EPA [and this website reproducing this public-domain article] seeks to promote energy efficiency and the safe use of ozone- friendly substances, and does not endorse any particular company or its products.

Background: Ban on Production and Imports of Ozone-Depleting Refrigerants

In 1987 the Montreal Protocol, an international environmental agreement, established requirements that began the worldwide phaseout of ozone-depleting CFCs (chlorofluorocarbons). These requirements were later modified, leading to the phase out in 1996 of CFC production in all developed nations. In addition, a 1992 amendment to the Montreal Protocol established a schedule for the phaseout of HCFCs (hydrochlorofluorocarbons). HCFCs are substantially less damaging to the ozone layer than CFCs, but still contain ozone-destroying chlorine. The Montreal Protocol as amended is carried out in the U.S. through Title VI of the Clean Air Act, which is implemented by EPA.

An HCFC known as R-22 has been the refrigerant of choice for residential heat pump and air-conditioning systems for more than four decades. Unfortunately for the environment, releases of R-22 that result from system leaks contribute to ozone depletion. In addition, the manufacture of R-22 results in a by-product that contributes significantly to global warming. As the manufacture of R-22 is phased out over the coming years as part of the agreement to end prouction of HCFCs, manufacturers of residential air conditioning systems are beginning to offer equipment that uses ozone-friendly refrigerants. Many homewners may be misinformed about how much longer R-22 will be available to service their central A/C systems and heat pumps. This fact sheet provides information about the transition away from R-22, the future availability of R-22, and the new refrigerants that are replacing R-22. This document also assists consumers in deciding what to consider when purchasing a new A/C system or heat pump, or when having an existing system repaired.

Phaseout Schedule for HCFCs used in Air Conditioning Equipment, Including R-22

Under the terms of the Montreal Protocol, the U.S. agreed to meet certain obligations by specific dates that will affect the residential heat pump and air-conditioning industry:

January 1, 2004 HCFC Refrigerant Reduction Target

In accordance with the terms of the Montreal Protocol, the amount of all HCFCs that can be produced nationwide must be reduced by 35% by 2004. In order to achieve this goal, the U.S. is ceasing production of HCFC-141b, the most ozone-damaging of this class of chemicals, on January 1, 2003. This production ban will greatly reduce nationwide use of HCFCs as a group, making it likely that the 2004 deadline will have a minimal effect on R-22 supplies.

January 1, 2010 HCFC Refrigerant Reduction Target

After 2010, chemical manufacturers may still produce R-22 to service existing equipment, but not for use in new equipment. As a result, heating, ventilation and air-conditioning (HVAC) system manufacturers will only be able to use pre-existing supplies of R-22 to produce new air conditioners and heat pumps. These existing supplies would include R-22 recovered from existing equipment and recycled.

January 1, 2020 HCFC Refrigerant Reduction Target

Use of existing refrigerant, including refrigerant that has been recovered and recycled, will be allowed beyond 2020 to service existing systems, but chemical manufacturers will no longer be able to produce R-22 to service existing air conditioners and heat pumps.

For more information about this phaseout, see fact sheets about the HCFC Phaseout Schedule and Frequently Asked Questions on the HCFC Phaseout.

What Does the R-22 Phaseout Mean for Consumers?

Availability of R-22

The Clean Air Act does not allow any refrigerant to be vented into the atmosphere during installation, service, or retirement of equipment. Therefore, R-22 must be recovered and recycled (for reuse in the same system), reclaimed (reprocessed to the same purity levels as new R-22), or destroyed. After 2020, the servicing of R-22-based systems will rely on recycled refrigerants. It is expected that reclamation and recycling will ensure that existing supplies of R-22 will last longer and be available to service a greater number of systems. As noted above, chemical manufacturers will be able to produce R-22 for use in new A/C equipment until 2010, and they can continue production of R-22 until 2020 for use in servicing that equipment. Given this schedule, the transition away from R-22 to the use of ozone-friendly refrigerants should be smooth. For the next 20 years or more, R-22 should continue to be available for all systems that require R-22 for servicing.

Cost of R-22

While consumers should be aware that prices of R-22 may increase as supplies dwindle over the next 20 or 30 years, EPA believes that consumers are not likely to be subjected to major price increases within a short time period. Although there is no guarantee that service costs of R-22 will not increase, the lengthy phaseout period for R-22 means that market conditions should not be greatly affected by the volatility and resulting refrigerant price hikes that have characterized the phaseout of R-12, the refrigerant used in automotive air-conditioning systems.

Alternatives to R-22 in Residential Air Conditioning

As R-22 is gradually phased out, non-ozone-depleting alternative refrigerants are being introduced. Under the Clean Air Act, EPA reviews alternatives to ozone-depleting substances like R-22 in order to evaluate their effects on human health and the environment. EPA has reviewed several of these alternatives to R-22 and has compiled a list of substitutes that EPA has determined are acceptable. One of these substitutes is R-410A, a blend of hydrofluorocarbons (HFCs), substances that do not contribute to depletion of the ozone layer, but, like R-22, contribute to global warming. R-410A is manufactured and sold under various trade names, including GENETRON AZ-20(R), SUVA 410A(R), and Puron(R). Additional refrigerants on the list of acceptable substitutes include R-134a and R-407C. These two refrigerants are not yet available for residential applications in the U.S., but are commonly found in residential A/C systems and heat pumps in Europe. EPA will continue to review new non-ozone-depleting refrigerants as they are developed.

Servicing existing A/C units

Existing units using R-22 can continue to be serviced with R-22. There is no EPA requirement to change or convert R-22 units for use with a non-ozone-depleting substitute refrigerant. In addition, the new substitute refrigerants cannot be used without making some changes to system components. As a result, service technicians who repair leaks to the system will continue to charge R-22 into the system as part of that repair.

Installing new Air Conditioning units

The transition away from ozone-depleting R-22 to systems that rely on replacement refrigerants like R-410A has required redesign of heat pump and air conditioning systems. New systems incorporate compressors and other components specifically designed for use with specific replacement refrigerants. With these significant product and production process changes, testing and training must also change. Consumers should be aware that dealers of systems that use substitute refrigerants should be schooled in installation and service techniques required for use of that substitute refrigerant.

A Common Sense Approach To Servicing Your System

Along with prohibiting the production of ozone-depleting refrigerants, the Clean Air Act also mandates the use of common sense in handling refrigerants. By containing and using refrigerants responsibly -- that is, by recovering, recycling, and reclaiming, and by reducing leaks -- their ozone depletion and global warming consequences are minimized. The Clean Air Act outlines specific refrigerant containment and management practices for HVAC manufacturers, distributors, dealers and technicians. Properly installed home comfort systems rarely develop refrigerant leaks, and with proper servicing, a system using R-22, R-410A or another refrigerant will minimize its impact on the environment. While EPA does not mandate repairing or replacing small systems because of leaks, system leaks can not only harm the environment, but also result in increased maintenance costs.

One important thing a homeowner can do for the environment, regardless of the refrigerant used, is to select a reputable dealer that employs service technicians who are EPA-certified to handle refrigerants. Technicians often call this certification "Section 608 certification," referring to the part of the Clean Air Act that requires minimizing releases of ozone-depleting chemicals from HVAC equipment.

A Common Sense Approach To Purchasing New Air Conditioning Systems

Another important thing a homeowner can do for the environment is to purchase a highly energy-efficient system. Energy-efficient systems result in cost savings for the homeowner. Today's best air conditioners use much less energy to produce the same amount of cooling as air conditioners made in the mid-1970s. Even if your air conditioner is only 10 years old, you may save significantly on your cooling energy costs by replacing it with a newer, more efficient model. Products with EPA's Energy Star(R) label can save homeowners 10% to 40% on their heating and cooling bills every year. These products are made by most major manufacturers and have the same features as standard products but also incorporate energy saving technology. Both R-22 and R-410A systems may have the Energy Star(R) label. Equipment that displays the Energy Star(R) label must have a minimum seasonal energy efficiency ratio (SEER). The higher the SEER specification, the more e fficient the equipment.

You should consider energy efficiency, along with performance, reliability and cost, in making your decision. And don't forget that when purchasing a new system, you can also speed the transition away from ozone-depleting R-22 by choosing a system that uses ozone-friendly refrigerants.

Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

AIR CONDITIONING SYSTEMS Chapter Index

To continue reading this air conditioning inspection guide, use links to the document chapters at left or below. Links shown in green font indicate where you are in this document.

  1. AIR CONDITIONING SYSTEMS HOME/A>
  2. A/C COMPONENTS
  3. CONTROLS & SWITCHES
  4. A/C DATA TAGS
  5. A/C TYPES, ENERGY SOURCES
  6. RATED COOLING CAPACITY
  7. SEER RATINGS
  8. A/C OPERATING COST
  9. SYSTEM OPERATION
  10. OPERATING TEMPERATURES
  11. OPERATING DEFECTS
  12. LOST COOLING CAPACITY
  13. COMPRESSOR CONDENSER
  14. AIR HANDLER UNIT
  15. AIR FILTERS for HVAC SYSTEMS
  16. CONDENSATE HANDLING
  17. CLEANING A/C EQUIPMENT
  18. DUCT SYSTEM DEFECTS
  19. A/C REFRIGERANTS
  20. INSPECTION LIMITATIONS
  21. CRITICAL DEFECTS

Technical Reviewers

Particular thanks are due to experts and also consumers who read these articles and suggest corrections, changes, and additions to the material. Content suggestions, technical corrections and content critique are invited for any of the content at our website.

  • Daniel Friedman - principal editor - document courtesy of the U.S. EPA
  • Critique, contributions wanted: Contact Us to suggest text changes and additions and, if you wish, to receive online listing and credit for that contribution.

More expert information on this topic


GO TO our MAIN WEB PAGE An ASHI Home Inspection, Environmental Inspection/Testing and Construction Information Website for Home Buyers, Owners, Inspectors Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice
InspectAPedia
Home
| Air
Conditioning
| Electrical | Environment | Exteriors | Heating | Home
Inspection
| Insulate
Ventilate
| Interiors | Mold
Inspect/Test
| Plumbing
Water
Septic
| Roofing | Structure | Contact Us
New Directory of Professionals to Inspect or Test a Building New

AIR CONDITIONING INSPECTION, DIAGNOSIS, REPAIR
A/C REFRIGERANTS
A/C DIAGNOSTIC FAQs
More Information

InspectAPedia TM Home & Site Map
Air Conditioning
InspectAPedia Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Bias Pledge
Contact Us

More Information on Air Conditioning Diagnosis and Repair, and Building Diagnostic Inspections and Repairs

goto InspectAPedia.com - authoritative, in-depth Building Diagnostic and Repair Information for building buyers, owners, inspectorsInspectAPedia TM Home & Site Map - Building Inspection, Diagnosis, & Repair, Environmental Inspection & Testing - Research Website

GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminantsThe Mold Information Center: What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems

GO TO MOLD TEST KITS: This expert-recommended mold test kit is cheap and yet top performing *IF* you use a competent analysis laboratory!Use this simple, economical mold test kit by following our instructions on how to collect and mail mold samples to our lab

GO TO IAQ/MOLD-TEST LAB SERVICES: Mold, Pollen, indoor air quality, field and laboratory services by an expert.Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.

GO TO our PRE PURCHASE BUILDING INSPECTION SERVICES: Authoritative information for home buyers and home owners is included with your inspection.Home Inspection Construction Consulting Services & advice for home buyers

CONTACT Daniel Friedman - Dan is a senior ASHI home inspector, nationally recognized expert on building inspection, building failures, and sick building investigationContact Daniel Friedman for website content suggestions or for fee-paid consulting

Google
 
Advertise on This Website →

05/22/07 - 04/12/2007 - www.inspect-ny.com/aircond/ACRefrigerantsEPA.htm - © 2008 Copyright Daniel Friedman All Rights Reserved