AMPS VOLTS DETERMINATION DEFINE AMPS VOLTS WATTS VISUALLY DETERMINE AMPS & VOLTS VOLTAGE at the SEC VOLTAGE by EQUIPMENT LIMITING FACTOR sets AMPS SE CABLE SIZES vs AMPS UNDERGROUND SERVICE LATERALS ALUMINUM SECs & WIRING MAIN DISCONNECT AMPACITY PANEL AMPACITY ELECTRIC METERS & METER BASES AMPACITY - the LIMITING FACTOR Article Reviewers More Information InspectAPedia TM Home & Site Map Air Conditioning InspectAPedia Bookstore Electrical Environment Exteriors Heating Home Inspection Insulate Ventilate Interiors Mold Inspect/Test Plumbing Water Septic Roofing Structure Accuracy & Bias Pledge Contact Us |
This article summarizes possible safety and functional concerns with the use of aluminum wiring for service entry cables or electrical panel components in buildings, and provides a link to the aluminum wiring information website. This is a chapter of our discussion of the inspection of electrical services at buildings in order to determine service capacity in volts and amps. © Copyright 2008 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website. ALUMINUM SECs & WIRING - Aluminum Service Cables and Wiring in Buildings for Electrical Service DeliveryIn both branch circuit and entrance cable wires, the permitted wire gauges for copper are normally one size smaller than for aluminum used at the same ampacity rating. This is because copper is a better conductor than aluminum. Aluminum wire must be larger to safely carry the same current as copper. Fire and Safety Issues with Aluminum Electrical WiringThere are important fire safety issues concerning the presence of aluminum branch circuit wiring in buildings - not discussed in this article. Solid aluminum branch conductors are no longer used in new wiring. Aluminum service entrance cables and aluminum single-purpose high-amperage circuits [NOTE: Such as for auxiliary sub-panels, central air conditioning or electric ranges.> are commonly installed in many communities. Many new electric service panels use plated aluminum parts. According to some experts risks remain even with these permitted applications in both the US [see "Reducing the Fire Hazard in Aluminum-Wired Homes," Jesse Aronstein, Ph.D., Wright Malta Corporation, Ballston Spa, NY, 1982] and Canada [see "Overheating Failures of Aluminum-Wired Special Service Connectors," Jesse Aronstein and Wilfred E. Campbell, IEEE Transactions on Components, Hybrids, and Manufacturing Technology, Vol. 4 CHMT-6, No.1, March 1983.] The risks of poor connections and fire hazards for aluminum SEC wiring are reduced by proper abrasion of the connected wires, proper tightening of the connector, and use of a special anti-corrosion flux compound. As recently as June 2006 we received a report of a major house fire which the owner asserts began at an overheating electrical service entry cable connector. Our opinion is that because the number of these connections is less than on a branch circuit wire, and possibly for other technical reasons involving the performance of multi-stranded aluminum wire, the risk of a fire is probably statistically less than with solid conductor branch circuits. It would appear that the risk is not as low as with copper service entry cables. Key References on Aluminum Electrical WiringThe Aluminum Wiring Information Website for a thorough discussion of aluminum branch circuit wiring concerns in the U.S. and in Canada as well. [There is disagreement among professionals about the Canadian risk and failure rate. Ontario Hydro and some Canadian inspection professionals do not acknowledge a significant risk from aluminum wiring in Canada. However the Scarboro development in Ontario demonstrated that failures and fires have occurred in that country.--DF] Use links at the left of each page or the links given just below to navigate this document or to view other topics at this website. Green links show where you are in our document or website. AMPS VOLTS DETERMINATION DEFINE AMPS VOLTS WATTS VISUALLY DETERMINE AMPS & VOLTS VOLTAGE at the SEC VOLTAGE by EQUIPMENT LIMITING FACTOR sets AMPS SE CABLE SIZES vs AMPS UNDERGROUND SERVICE LATERALS ALUMINUM SECs & WIRING MAIN DISCONNECT AMPACITY PANEL AMPACITY ELECTRIC METERS & METER BASES ELECTRIC METER BASES ELECTRIC METERS INSPECTING METERS & BASES AMPACITY - the LIMITING FACTOR Technical ReviewersParticular thanks are due to experts and also consumers who read these articles and suggest corrections, changes, and additions to the material. Content suggestions, technical corrections and content critique are invited for any of the content at our website.
Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website. More expert information on Inspecting Electrical Equipment and Electrical Safety for Inspectors | |
|
AMPS VOLTS DETERMINATION DEFINE AMPS VOLTS WATTS VISUALLY DETERMINE AMPS & VOLTS VOLTAGE at the SEC VOLTAGE by EQUIPMENT LIMITING FACTOR sets AMPS SE CABLE SIZES vs AMPS UNDERGROUND SERVICE LATERALS ALUMINUM SECs & WIRING MAIN DISCONNECT AMPACITY PANEL AMPACITY ELECTRIC METERS & METER BASES AMPACITY - the LIMITING FACTOR More Information InspectAPedia TM Home & Site Map Air Conditioning InspectAPedia Bookstore Electrical Environment Exteriors Heating Home Inspection Insulate Ventilate Interiors Mold Inspect/Test Plumbing Water Septic Roofing Structure Accuracy & Bias Pledge Contact Us |
More Information on Electrical Inspections & Building Diagnostic Inspections and Repairs
|
10/21/2007 - 1/16/1993 www.inspect-ny.com/electric/ElecAmps6.htm - Web page design & content © 2007-1993 Copyright Daniel Friedman All Rights Reserved