AMPS VOLTS DETERMINATION DEFINE AMPS VOLTS WATTS VISUALLY DETERMINE AMPS & VOLTS VOLTAGE at the SEC VOLTAGE by EQUIPMENT LIMITING FACTOR sets AMPS SE CABLE SIZES vs AMPS UNDERGROUND SERVICE LATERALS ALUMINUM SECs & WIRING MAIN DISCONNECT AMPACITY PANEL AMPACITY ELECTRIC METERS & METER BASES ELECTRIC METER BASES ELECTRIC METERS INSPECTING METERS & BASES AMPACITY - the LIMITING FACTOR Article Reviewers More Information InspectAPedia TM Home & Site Map Air Conditioning InspectAPedia Bookstore Electrical Environment Exteriors Heating Home Inspection Insulate Ventilate Interiors Mold Inspect/Test Plumbing Water Septic Roofing Structure Accuracy & Bias Pledge Contact Us |
This article explains how to estimate the electrical service size, (or "electrical power" or "service amps") at a building by visual examination of the service entry cables, electric meter and meter base, electrical service panel, main switch, and other details. Visual inspection and use of digital multimeters(DMMs), Volt-ohm meters (VOMs), neon testers, and electrical inspection safety are discussed. Photographs and sketches illustrate electrical panels, meter bases, and electric meters. One of the most frequently asked questions at ASHI Education Seminars and Conferences is "How do I determine the service amperage?" It's not as difficult as one may think to get a reasonable handle on the electrical service capacity at a building without sophisticated analysis. But there are some pitfalls, and the process itself is dangerous. The articles from which much of this online material originated appeared first in the ASHI Technical Journal, Vol. 2. No. 1, January 1992, "Determining Service Ampacity," Dan Friedman and Alan Carson, and the ASHI Technical Journal, Vol. 3. No. 1, Spring, 1993, "Determining Service Ampacity - Another Consideration," Robert L. Klewitz, P.E., with subsequent updates and additions to the original text ongoing to 2/19/2006. Reprints of the originals and reprints of the Journal are available from ASHI, the American Society of Home Inspectors www.ashi.com Readers of this article should also be sure to review Safety Hazards and Safe Electrical Inspection Procedures for examining Residential Electrical Panels. © Copyright 2008 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.VOLTAGE at the SEC - How to figure out Electrical Service Voltage by visual examination at the service entry
However simple visual examination from the ground is not a certain proof of voltage available in the building. In a few unusual circumstances, all three wires may be present but one of them may be disconnected at the utility pole or masthead. Such "mistakes" occur during temporary hookups in new construction or renovation. Could there be 240V service to a building with only two wires? Yes but not normally in the U.S. Some Canadian rural properties served by long private wires may have only two overhead conductors on a 240 volt service. For these systems ground connections are made only at the building, not back to the utility company's lines. In the U.S. this would be unusual but be alert for it, especially at rural properties.
Notes to Table:
Use links at the left of each page or the links given just below to navigate this document or to view other topics at this website. Green links show where you are in our document or website. AMPS VOLTS DETERMINATION DEFINE AMPS VOLTS WATTS VISUALLY DETERMINE AMPS & VOLTS VOLTAGE at the SEC VOLTAGE by EQUIPMENT LIMITING FACTOR sets AMPS SE CABLE SIZES vs AMPS UNDERGROUND SERVICE LATERALS ALUMINUM SECs & WIRING MAIN DISCONNECT AMPACITY PANEL AMPACITY ELECTRIC METERS & METER BASES ELECTRIC METER BASES ELECTRIC METERS INSPECTING METERS & BASES AMPACITY - the LIMITING FACTOR Technical ReviewersParticular thanks are due to experts and also consumers who read these articles and suggest corrections, changes, and additions to the material. Content suggestions, technical corrections and content critique are invited for any of the content at our website.
Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website. More expert information on Inspecting Electrical Equipment and Electrical Safety for Inspectors | ||||||||||||||||||||||||||
|
AMPS VOLTS DETERMINATION DEFINE AMPS VOLTS WATTS VISUALLY DETERMINE AMPS & VOLTS VOLTAGE at the SEC VOLTAGE by EQUIPMENT LIMITING FACTOR sets AMPS SE CABLE SIZES vs AMPS UNDERGROUND SERVICE LATERALS ALUMINUM SECs & WIRING MAIN DISCONNECT AMPACITY PANEL AMPACITY ELECTRIC METERS & METER BASES AMPACITY - the LIMITING FACTOR More Information InspectAPedia TM Home & Site Map Air Conditioning InspectAPedia Bookstore Electrical Environment Exteriors Heating Home Inspection Insulate Ventilate Interiors Mold Inspect/Test Plumbing Water Septic Roofing Structure Accuracy & Bias Pledge Contact Us |
More Information on Electrical Inspections & Building Diagnostic Inspections and Repairs
| ||||||||||||||||||||||||||
10/21/2007 - 1/16/1993 www.inspect-ny.com/electric/ElecSECVolts.htm - Web page design & content © 2007-1993 Copyright Daniel Friedman All Rights Reserved