Mobile View
ELECTRICAL INSPECTION, DIAGNOSIS, REPAIR
AFCIs ARC FAULT CIRCUIT INTERRUPTERS
ALUMINUM SECs & WIRING
ALUMINUM WIRING HAZARDS
AMPS & VOLTS DETERMINATION
CIRCUIT BREAKER FAILURE
Classified CIRCUIT BREAKER WARNING
DEFINITIONS of ELECTRICAL TERMS
DIRECTORY OF ELECTRICIANS
ELECTRIC METERS & METER BASES
ELECTRIC PANEL AMPACITY
ELECTRIC PANEL INSPECTION
ELECTRICAL BASICS
Electricity Basics - how it works
Electrical Circuit ID, Map & Label
Electrical Circuits, shorts
Electrical Code Basics
Electrical Conduit Tips
Electrical Definitions
Electrical Grounding Basics
Electrical Outlet-how to add
Electrical Splices, how to make
Electrical Tools & Tests
Electrical Wire Stripping Tips
Electrical Wiring Books & Guides
Electrical Wiring in Old Houses
Grounding
Voltage Available
Amperage Available
Knob-and-tube wiring
Electrical Shorts
Number of Circuits
Polarized Plugs, Receptacles, Lights
FEDERAL PACIFIC FPE HAZARDS
GROUND SYSTEM INSPECTION
KNOB & TUBE WIRING
LIGHTNING PROTECTION
LOW VOLTAGE BUILDING WIRING
MAIN DISCONNECT AMPACITY
MULTI-WIRE CIRCUITS
RUST in ELECTRICAL PANELS
SAFETY FOR ELECTRICAL INSPECTORS
SE CABLE SIZES vs AMPS
SQUARE-D RECALLS
UNDERGROUND SERVICE LATERALS
VOLTAGE MEASUREMENT EQUIPMENT
ZINSCO / SYLVANIA HAZARDS
InspectAPedia ® Home & Site Map
Air Conditioning
InspectAPedia Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Bias Pledge
Contact Us
|
Old House Wiring Inspection & Repair: Electrical Grounding, Knob & Tube, & Electrical Wiring in Older Buildings
ElectricAPedia ©
|
- How to inspect & repair or improve electrical grounding in older homes
- How to detect & repair improper electrical outlet polarity.
- How to determine what voltage and amperage service a home
- How to recognize knob and tube electrical wiring and unsafe "extension cord" wiring
- How to evaluate the number of electrical circuits in an older home
- Guide to Electrical Hazards in Buildings: inspection, detection, & repair advice
Our site offers impartial, unbiased advice without conflicts of interest.
We will block advertisements which we discover or readers inform us are associated with bad business practices,
false-advertising, or junk science. Our contact info is at inspect-ny.com/appointment.htm.
This article answers basic questions about assessing the electrical service, capacity, wiring type, condition, and safety in older homes. Readers of this article should also see ELECTRICAL DEFINITIONS. This website provides information about a variety of electrical hazards in buildings, with articles focused on the inspection, detection, and reporting of electrical hazards and on proper electrical repair methods for unsafe
electrical conditions. Critique and content suggestions are invited. Credit is given to content editors and contributors.
© Copyright 2008 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website. Sketch at page top courtesy of Carson Dunlop.
Electrical Grounding & Other Electrical Safety Concerns in Older Homes
Elizabeth Sluder & Daniel Friedman
Older homes often have electrical receptacles and fixtures that are ungrounded, and many local codes do not require that they be rewired so they're grounded. Still, grounding is worth adding to your system because it adds protection against electrical shock. Grounding provides a third path for electricity to travel along, so if there is a leak of any sort, it will flow into the earth rather than into the body of a person who touches a defective fixture, appliance, or tool.
An electrical system is grounded with a grounding rod driven at least 8 feet into the ground outside the house or by connecting to a cold water pipe. Each individual branch circuit must be grounded as well, either with a separate wire that leads to the neutral bar of the service panel or with metal sheathing that runs without a break from each outlet to the panel. (In theory, electrical outlets can be grounded individually, but this is impractical.)
Absence of good electrical grounding at older homes
|

Do Older Homes Have Proper & Safe Electrical Ground Wiring?
Often an older building has poor or no working local electrical ground, relying instead on the incoming neutral wire from the electrical service.
Or the building's main electrical ground may have relied on connection to a metal water pipe connected to a well; we've found building ground wires connected to a metal water pipe which used to run out of the building and into earth (possibly a pretty effective ground) but where the metal piping exiting the building had been replaced with a newer plastic water line between the well and the building. In other words the local ground was completely ineffective.
Modern electrical grounding at residential properties requires use of one or more grounding electrodes connected by an un-spliced wire between the electrode and the ground and neutral bus in the main electrical panel.
Bare aluminum electrical ground wires are sometimes found to have corroded entirely through where the wire touched a damp foundation wall. We also find that the ground wire between the electrical panel and a building water pipe or grounding electrode has become separated, loose, spliced, or lost entirely, as shown in our photo. |
Ungrounded, un polarized electrical circuits in older homes
If your outlets have two slots that are the same size, then they are neither polarized nor grounded. This leaves you with no protection against shocks from defective fixtures or appliances using that outlet. At the very least, you need to install polarized outlets. You cannot and should not install grounded electrical outlets on circuits where no ground path is actually present (such as knob and tube wiring). To provide a grounded outlet where no ground is present is dangerous.
Some locations in your house- especially where the outlet and/or appliances may become wet- require ground-fault circuit-interrupter (GFCI) receptacles. Older, ungrounded circuits usually are protected by polarization, which is less effective than grounding but better than nothing. Grounded and polarized receptacles work only if they are wired correctly.
An older home may have electrical service that is inadequate or even unsafe. It can be confusing, as well. If you are unsure about your home’s wiring, have a professional check it out.
See Electrical Outlet-how to add and ELECTRICAL GROUND SYSTEM INSPECTION for details about electrical wiring of receptacles (outlets or "wall plugs") and how to inspect the electrical grounding system at a building.
Voltage Available at Older Homes
|
Some older homes have only 120-volt electrical service. The electrical cable bringing electricity to the building provides two wires - one live or "hot" (rather than two) and a neutral entering the house.
This means you will not be able to have any 240-volt circuits or large appliances.
Our photo shows a single hot wire and a single neutral wire which is grounded by the utility company somewhere upstream from this home.
See DEFINITIONS of ELECTRICAL TERMS if you're not sure about the definitions of volts.
See AMPS VOLTS DETERMINATION for a detailed procedure on determining the whether your building is served by 120V or 240V.
|
Amperage Available at Older Homes
|
Modern electrical service provides at least 100 amps of power, which is enough to power, a medium-size house with average number of appliances. A house built in the 1950s or before may only have 30-amp service (the circuit box will have only two fuses) or 60-amp service (four fuses - see our photo). With so few circuits, the number of appliances you can run will be limited.
Even if a building has had additional electrical circuits installed, thus improving the distribution of electrical power in the home, if the main electrical panel has not been up-graded it is possible that it is too small for the current usage in the building.
If your building has been wired correctly, the circuit breakers or fuses should protect the building from a fire due to overloaded circuits, and what will remain is an inconvenience: having to replace fuses or re-set circuit breakers.
If the building wiring is incorrect, damaged, or obsolete, the combination of those conditions with insufficient incoming building amperage may increase the risk of fire.
See DEFINITIONS of ELECTRICAL TERMS if you're not sure about the definitions of Amps, Watts, or similar electrical terms.
See AMPS VOLTS DETERMINATION for a detailed procedure on determining the ampacity available at a building. |
Some Potential Electrical Problems in Older Home
Here are a few things to consider when inspecting the electrical system in an older home.
Warning: this list of electrical wiring defects and safety concerns in older homes is incomplete. Contact Us to suggest corrections, changes, or to add additional items.
Knob-and-tube wiring in older homes
|
Knob and tube electrical of wiring has been installed in homes from the 1920s right up into the 1970's in some jurisdictions.
Knob and tube electrical wiring may be functional in a home and it was in its original concept a safe wiring method, separating the two conductors in air (see our photo at left) and using durable ceramic insulating knobs and tubes to mount the wire.
Knob and tube electrical wiring may not need to be replaced, but it certainly deserves careful inspection and possibly replacement or repair, because knob and tube systems lack an electrical ground (less safe), may have damaged insulation (less safe), or may have been improperly modified or extended (unsafe).
Please see Knob and Tube Electrical Wiring for a detailed discussion of the identification, inspection, and repair of this electrical wiring system.
Sources of electrical shorts and wiring faults in older homes
Loose taped wires, old wire damaged because it’s exposed, and multiple wires slipping off a single terminal screw may seem like minor problems, but are not.
See Electrical Circuits, shorts for more about short circuits, how they happen, how they are corrected. |
Insufficient number of electrical circuits in older homes
|
As modern homes use more appliances and more electricity than folks did even twenty years ago, if the number of circuits in a home has not been increased it's likely that the home's electrical circuits are overloaded.
Too often in an older home we find that the electrical circuits have been "extended" by someone who has no idea about safe electrical wiring. People use lamp cord (Zip cord) or extension cords as permanent circuits, sometimes even routing such wires through walls and ceilings - a fire hazard, and certainly not in compliance with electrical codes.
At an inspection where we found lamp cord run through a wall to add wall-mounted lighting, a by standing real estate agent later asked the tenant to simply "cut and remove the wiring" - leading to a serious electrical shock event. It would have been a better idea to hire a licensed electrician.
Too often in an older home, especially one using a fuse panel, occupants are tempted to simply screw in a higher-amperage fuse to stop fuses from 'blowing". Over-fusing is dangerous: it risks setting the building on fire. Be sure that the amperage rating of your fuses or circuit breakers matches the wiring of each circuit: |
- A 15-amp fuse or circuit breaker is what's needed on a 15-Amp #14-gauge copper electrical wire.
- A 20-amp fuse or circuit breaker can be used on a 20-Amp #12-gauge copper electrical wire.
For an example of installing an additional electrical receptacle, see Electrical Outlet-how to add.
Warnings about Polarized Electrical Plugs, Receptacles, and Lighting Fixtures
"Polarity" in an electrical receptacle and on the device that plugs into or connects to it means that we're making sure that we connect the "hot" or "live" side of the electrical circuit to the connection point in the appliance or device that was intended to be "hot" or "live".
Carson Dunlop's sketches show why it's important to respect polarity when connecting an electrical receptacle, a lamp or any other appliance.
Never clip or file down the prongs on a grounded or polarized plug in order to force it to fit into an older electrical receptacle. The risk is that your plug will be installed with reversed polarity - connecting the "hot" side of the electrical circuit to the normally neutral-wired side of the appliance. We've found appliances (a coffee maker) that simply burned up when connected in this fashion.
Go to the heart of the problem: Test and upgrade your electrical circuit system.
See ELECTRICAL GROUND SYSTEM INSPECTION for details about how to inspect the electrical grounding system at a building. Also, see details about electrical grounding at Electrical Circuits, shorts, and at Electrical Wiring in Old Houses and at Electricity Basics - how it works.
Safety Warning:
Do not attempt to work on your electrical wiring, switches, or outlets unless you are properly trained and equipped to do so. Electrical components in a building can easily cause an electrical shock, burn, or even death.
Even when a hot line switch is off, one terminal on the switch is still connected to the power source. Before doing any work on the switch, the power source must be turned off by setting a circuit breaker to OFF or removing a fuse. See SAFETY FOR ELECTRICAL INSPECTORS and Electrical Wiring Books & Guides
|
Technical Reviewers & References
Particular thanks are due to experts and also consumers who read these articles and suggest corrections, changes, and additions to
the material. Content suggestions, technical corrections and content critique are invited for any of the content at our website.
- Daniel Friedman - principal author/editor of the InspectAPedia TM Website
- Elizabeth Sluder, Montross, VA, the original author of this article, is a public school teacher who writes basic educational articles about a variety of building, construction, and other topics. Her husband, a licensed electrician, consults for her writing on electrical topics. Her articles appearing at the InspectAPedia TM Website have been edited, illustrated, and on occasion content has been added by the website author. These articles are © 2008 InspectAPedia copyright-protected, all rights reserved.
- Thanks to Alan Carson and Bob Dunlop, Carson Dunlop, Associates, Toronto, for permission to use illustrations from their publication, The Illustrated Home which illustrates construction details and building components. Carson Dunlop provides home inspection education, publications, report writing materials, and home inspection services. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
- Critique, contributions wanted: Contact Us to suggest text changes and additions and, if you wish, to receive online listing and credit for that contribution.