ELECTRICAL INSPECTION, DIAGNOSIS, REPAIR
FPE Stab-Lok HAZARDS & REPAIRS WEBSITE
SUMMARY OF the FPE Stab-Lok PROBLEM
FPE HAZARD ARTICLES, STUDIES
FPE Stab-Lok TECHNICAL REPORT
HOW TO IDENTIFY FPE & FP
REPORTS OF FPE FAILURES
HOW TO REPORT FPE INCIDENTS
FPE REPAIR ELECTRICIANS
FPE REPLACEMENT BREAKERS
FPE REPLACEMENT PANELS
FPE REPLACEMENT PANEL COSTS
CAN'T AFFORD A NEW ELECTRIC PANEL?
CANADIAN VERSIONS of FPE Stab-Lok
FPE Stab-lok: FIRES WAITING TO HAPPEN
ADVICE TO HOME BUYERS w/ FPE PANELS
HOME INSPECTION LANGUAGE for FPE Stab-Lok
IAEI LETTER

More Information

InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
Contact Us

FPE breaker failed to trip - this is a typical breaker overheat example provided by Mark Cramer, a Tampa Florida home inspectorFederal Pacific Electric Stab-Lok Letter to IAEI
FPEaPedia ©

  • 1999 Letter written to IAEI magazine in response to an "infomercial" denying failure issues with FPE Stab-lok equipment
  • 2007 Response to the letter, from IAEI or its editor [None]

We recommend that the FPE Stab-Lok electrical panel be replaced entirely. We recommend against replacing individual FPE Stab-lok circuit breakers. We do not sell circuit breakers nor any other products. Our site offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at inspect-ny.com/appointment.htm.

This website explains the fire and shock hazards associated with Federal Pacific Electric Stab-lok circuit breakers and service panels, provides a history of the issue, recounts research on FPE failures, and recommends replacement of the panels. panel replacement or repair. The web author has no business, financial, or other connection with FPE products nor with their replacement.

Electronic copies and reproduction of this information at other websites are prohibited. Readers are welcome to make and distribute printed copies of our articles about FPE Stab-Lok equipment provided this web page is cited and provided that the content is not edited or changed. (Contact us to suggest edits, changes, corrections, updates). © Copyright 2009 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

Letter to IAEI International Association of Electrical Inspectors News Magazine re: FPE Public Relations Article asserts Federal Pacific Electric Stab-Lok panels are OK.

8/11/99

International Association of Electrical Inspectors
ATTN: Philip H. Cox, Editor-in-Chief, IAEI Magazine
PO Box 830848
Richardson TX 75083-0848

Dear Mr. Cox:

The May/June '99 IAEI News article by an unidentified FPE consultant asserts that Federal Pacific Electric Stab-Loks are UL-Listed and thus without any concern. The article fails to address a record of failures to trip, actual test results, field reports of failures, and improper UL listing practices. The FPE author and IAEI News failed to report on the actual website content, failed to contact the author, and failed to give the correct website address so that readers could judge for themselves. I am an IAEI member and the author of the informational website for home inspectors which was referred-to in the FPE article. The correct Internet website address is http://inspect-ny.com/fpe/fpepanel.htm

Publicly available information is compelling and sufficient to warrant warning contractors, inspectors, and consumers. The best data available substantiates that the 2-pole breakers cannot be relied upon to trip. CPSC found that was the case. FPE agreed that was the case. Field reports confirm that is still the case. Inspectors should work towards replacing breakers that won't trip, not towards whitewashing the problem.

The problem with FPE breakers is that a significant portion of them will not trip on overload or short circuit conditions in order to protect a building from fire ignition. Testing done by the CPSC showed that at a modest overload on both poles these failed 25% of the time, followed by a lockup. The breaker would never trip in the future at any overload. (See Table 1, Summary of Failures, CPSC-C-81-1429 December 30, 1982, attached.) There are other types of failures known to occur in FPE panels at lower probability and not as well documented as the 2-pole no-trip problem.

FPE did not refute the CPSC's test data. The no-trip problems with 2-pole Stab-Lok breakers were acknowledged by FPE. FPE claims that when their circuit breakers do not trip it does not constitute a hazard. The article in IAEI News by FPE is asking us to agree with FPE's position that breakers that won't trip are OK because they are "listed and labeled." Let's keep in mind that a breaker that will not trip on certain overcurrent conditions is electrically the same as an Edison-base fuse with a penny behind it. No inspector should be encouraged to condone or whitewash the continued use of breakers that cannot be depended on to trip properly.

These problems were known. Reliance Electric Co. had bought FPE in 1979 when they discovered problems with FPE breakers. They sued the company they had bought FPE from, claiming undisclosed potential liability made FPE not what they had bargained for and citing evidence that "improper and deceptive practices were employed for many years to secure UL listings for Federal Pacific's circuit protective products? They wanted their money back. Reliance eventually settled the suit, kept FPE, and got back $41.85 million in return for which they agreed to indemnify the company they'd bought FPE from for product liability claims arising from products made by FPE before the purchase.

Continuing problems can't be ruled out. For example, see the Federal Pacific/Federal Pioneer circuit breaker warranty alert issued by the Ontario New Home Warranty Program in 1997 (copy attached). These products are still present in the field! Reports from consumers and electricians indicate failures to trip, overheating, and fires.

Note also that the author of the FPE article did not want to have his or her name associated with it and that the FPE contact listed is an attorney retained (presumably) by FPE. The information address given in the article would have been more accurate if given as: Howard B. Abramoff Law Offices, 25700 Science Park Dr. Suite 260, Cleveland OH 44122. This is a law firm, not a circuit-breaker manufacturer. This confirms that the article is biased towards the defense of FPE rather than providing information on "?the safe installation and use of electricity" (IAEI's mission statement in the magazine's masthead).

As a neutral professional, I'd be pleased to receive reliable information shedding new light on the situation. But a public relations article written by someone whose aim is to protect FPE's interests and which fails to address legitimate concerns and the known failures and problems occurring around the country is not something I'd rely upon. Based on my experience and numerous reports from people with no axes to grind, it appears that FPE circuit breakers frequently fail to perform their function. A circuit breaker may sit in a building for twenty years, and as long as it never sees an overload or short circuit it may seem to work fine. But if it cannot perform its function to interrupt current when overloaded or short circuited, that circuit breaker is a latent fire hazard. Such equipment should be replaced.

Respectfully,

Dan Friedman, IAEI #195930

Attachments:

1. "Calibration and Condition Tests of Molded Case Circuit Breakers, Final Report: Contract CPSC-C-81-1429," December 30, 1982, Wright Malta Corporation, Summary Pages 1-3.

2. Reliance Electric Co. Press Release, July 7, 1980, stating that "Underwriters Laboratories labels for most of FPE's circuit breakers were obtained through improper practices,?

3. Schneider Electric Canada Warranty Alert, recalling Federal Pioneer (Federal Pacific Canadian) circuit breakers NC015/NC015P, October 14, 1997

4. My resume/background (Since the article indicates the author did not know who I am)

5. WEB FaqS: Website author, credibility

6. "Federal Pacific Electric (FPE) Panels, a Summary," website page from http://inspect-ny.com/fpe/fpepanel.htm (This is the root page of a collection of public documents and articles regarding this topic.)

02/10/2009 follow-up note: IAEI never responded to this correspondence.
05/28/2008 follow-up note: IAEI did not respond to this correspondence
06/01/07 follow up note: IAEI and Mr. Cox have not replied to this correspondence.
10-1-00 follow up note: IAEI and Mr. Cox have declined to reply to this correspondence.
03/01/03 follow up note: IAEI has not retracted the un-signed article described above. Industry experts have confirmed that the IAEI article is inaccurate and dangerous in its advice as it exposes consumers to equipment which cannot be relied upon in event of an overcurrent. The result could be shock or fire. I have encountered one or two instances of electricians who, unfamiliar with FPE failures, cited this article in defense of a "no action" position, in all cases in defense of a home seller. My advice to consumers who are faced with denials that this equipment is a latent safety hazard to ask for that opinion in writing. To date (12/1/2005) I have not had any reports of a professional who was willing to sign such a document.
01/26/2006 follow up note: IAEI declined to ever address the dangerous inaccuracies in the original IAEI magazine article. The article appears to have been penned by an attorney charged with protecting the remaining interests of that organization.

...

Technical Reviewers & References

  • Daniel Friedman - principal author/editor of the InspectAPedia® Website
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also include a list of recommended books for the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

FPE Stab-Lok HAZARDS & REPAIRS WEBSITE
SUMMARY OF the FPE Stab-Lok PROBLEM
FPE HAZARD ARTICLES, STUDIES
FPE Stab-Lok TECHNICAL REPORT
HOW TO IDENTIFY FPE & FP
REPORTS OF FPE FAILURES
HOW TO REPORT FPE INCIDENTS
FPE REPAIR ELECTRICIANS
FPE REPLACEMENT BREAKERS
FPE REPLACEMENT PANELS
FPE REPLACEMENT PANEL COSTS
CAN'T AFFORD A NEW ELECTRIC PANEL?
CANADIAN VERSIONS of FPE Stab-Lok
FPE Stab-lok: FIRES WAITING TO HAPPEN
ADVICE TO HOME BUYERS w/ FPE PANELS
HOME INSPECTION LANGUAGE for FPE Stab-Lok
IAEI LETTER

  • Note: as we didn't add this reviewers list until 2007, this list of technical reviewers is incomplete; we have received comments and suggestions regarding this topic, edits and remarks included, from engineers and management from the US CPSC, electricians (many listed at our page on field reports of FPE failures), home inspectors, licensed electricians, and electrical engineers, and even a few attorneys and real estate agents, since 1986. Technical review, critique, content suggestions, questions, or clarifications are invited and where a contributor wishes, credit and links will be provided to that source. Contact us to provide feedback.
  • Dr. Jess Aronstein, electrical engineer, Poughkeepsie, NY, forensic engineering services, independent laboratory testing for various agencies
  • Alan Carson, Carson Dunlop Associates, Toronto, Ontario. Mr. Carson is a home inspection professional, educator, researcher, writer, and a principal of Carson Dunlop Associates, a Toronto home inspection and education firm. Mr. Carson is a past president of ASHI, the American Society of Home Inspectors
  • Mark Cramer Inspection Services Mark Cramer, Tampa Florida, Mr. Cramer is a past president of ASHI, the American Society of Home Inspectors and is a Florida home inspector and home inspection educator.
  • Carl Grasso, Esq., Herzfeld & Rubin, New York, NY. Mr. Grasso is an attorney who managed a plaintiff's class action litigation against Federal Pacific Electric in New Jersey.
  • William King, US CPSC Director of Electrical Engineering (Ret).
  • Licensed Electricians: FPE Fire and Failure Reports includes electricians who have provided cases and photographs of field failures of FPE equipment at this website.
  • Homeowners, Home Inspectors, Electricians: Federal Pacific Electric (FPE) Panel Fires and other Failures includes anecdotal field reports provided by a range of contributors including electricians (and some home owners or home inspectors) who have provided cases and photographs of field failures of FPE equipment at this website.
  • Daniel Friedman - principal author/editor of the InspectAPedia® Website
  • Technical reviewers are invited to comment or ask questions - contact us

Exxon Buys a Scandal ... - Business Week July 21 1980
p.66Exxon Buys A Scandal Along With A Company - Business Week, July 21, 1980, p.66

For faster loading, this article, obtained from a public library, has been broken into segments. Use the links below to read the article in order; use the "back" button on your browser to return to this page.

The Consumer Product Safety Commission advises consumers to take certain safety precautions with all circuit breakers and fuses. Consumers should:

-Know your electrical circuit. Know which outlets and products are connected to each circuit.

-Never overload any electrical circuit by connecting too many products to the circuit. Be particularly careful not to connect several products that demand high current (such as heating appliances) to a low amperage circuit.

-Comply with local building codes in wiring or adding electrical circuits. Make sure the wiring and devices used in the circuit are connected to a circuit breaker or fuse of the

-Immediately disconnect any electrical product if problems develop. Have the product examined by a competent repair person.

-Investigate to determine why a fuse blows or circuit breaker trips. Do not simply replace the fuse or reset the breaker. If a fuse blows or breaker trips, it is often a warning that the circuit is overloaded. Check the circuit for causes of overloading (for example, too many appliances plugged in, a malfunctioning product, a short circuit). When in doubt, consult a licensed electrician.

Consumers who have questions concerning circuit breakers, or who wish to report information relating to their safety, may call the U.S. Consumer Product Safety Commission's toll-free safety hotline at 800-638-CPSC, teletypewriter for the hearing impaired at 800-638-8270 (Maryland only 800-492-8104).

FPE Stab-Lok HAZARDS & REPAIRS WEBSITE

More Information

InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
Contact Us

More Information on Building Diagnostic Inspections and Repairs

InspectAPedia.comInspectAPedia® Home & Site Map - Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice: In-depth research & advice on diagnosing, testing, correcting, & preventing building defects & indoor environmental hazards. Unbiased information, no conflicts of interest.
GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminants
The Mold Information Center:
What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
GO TO MOLD TEST KITS: This expert-recommended mold test kit is cheap and yet top performing *IF* you use a competent analysis laboratory!
Use this simple, economical mold test kit
by following our instructions on how to collect and mail mold samples to our lab
GO TO IAQ/MOLD-TEST LAB SERVICES: Mold, Pollen, indoor air quality, field and laboratory services by an expert.Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.
GO TO our PRE PURCHASE BUILDING INSPECTION SERVICES: Authoritative information for home buyers and home owners is included with your inspection.
Building Inspection, Problem Diagnosis
, Forensic Investigation & Testing, Repair Consulting

CONTACT Daniel Friedman - Dan is a senior ASHI home inspector, nationally recognized expert on building inspection, building failures, and sick building investigation
Contact Daniel Friedman for website content suggestions or for fee-paid consulting

04/15/2009 - 05/28/2008 InspectA- © 2009 - 1988 Copyright Daniel Friedman All Rights Reserved - InspectAPedia® is a Registered U.S. Trademark