FPE CPSC Information
ELECTRICAL INSPECTION, DIAGNOSIS, REPAIR
FPE Stab-Lok HAZARDS & REPAIRS WEBSITE
SUMMARY OF the FPE Stab-Lok PROBLEM
FPE HAZARD ARTICLES, STUDIES
FPE Stab-Lok TECHNICAL REPORT
HOW TO IDENTIFY FPE & FP
REPORTS OF FPE FAILURES
HOW TO REPORT FPE INCIDENTS
FPE REPAIR ELECTRICIANS
FPE REPLACEMENT BREAKERS
FPE REPLACEMENT PANELS
FPE REPLACEMENT PANEL COSTS
CANADIAN VERSIONS of FPE Stab-Lok
FPE Stab-lok: FIRES WAITING TO HAPPEN
ADVICE TO HOME BUYERS w/ FPE PANELS
HOME INSPECTION LANGUAGE for FPE Stab-Lok
IAEI LETTER
More Information
InspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
Contact Us
|
Federal Pacific Electric (FPE) Panels - CPSC Information FPEaPedia ©
- The closing statement regarding a CPSC Investigation of FPE Circuit Breakers and more safety advice for FPE Stab-Lok breakers
Our site offers impartial, unbiased advice without conflicts of interest.
We will block advertisements which we discover or readers inform us are associated with bad business practices,
false-advertising, or junk science. Our contact info is at
inspect-ny.com/appointment.htm.
This page contains a closing statement regarding a CPSC Investigation of FPE Circuit Breakers and additional safety information for consumers.
Click your browser's "back" button to return to the previous page or use links at the page bottom.
NOTE: This document has been entered verbatim from the original document. Important
safety remarks and independent study reports of FPE hazards and advice about what to do can be found
at More Information about FPE below.
© Copyright 2009 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.
FOR RELEASE: MARCH 3, 1983
U.S. Consumer Product Safety Commission
CLOSES INVESTIGATION OF
FPE CIRCUIT BREAKERS AND PROVIDES
SAFETY INFORMATION FOR CONSUMERS
WASHINGTON, D.C. -- The Consumer Product Safety Commission
announced today that it is closing its two year investigation into
Federal Pacific Electric Stab-lok type residential circuit breakers.
This action was taken because the data currently available to the
Commission does not establish that the circuit breakers present a
serious risk of injury to consumers.
The Commission investigation into Federal Pacific Electric (FPE)
circuit breakers began in June, 1980, when Reliance Electric Co., a
subsidiary of Exxon Corporation and the parent to FPE, reported to
the Commission that many FPE circuit breakers did not fully comply
with Underwriters Laboratories, Inc. (UL) requirements. Commission
testing confirmed that these breakers fail under certain UL calibration
test requirements. The Commission investigation focused primarily
on 2-pole residential circuit breakers manufactured before Reliance
acquired FPE in 1979.
To meet UL standards, residential circuit breakers must pass
a number of so-called "calibration tests." The purpose of these
tests is to determine whether the circuit breakers will hold the
current for which they are rated and also automatically open or
"trip" (shut off the current) within the specified time limits if
over-loading of the circuit breakers causes current levels in excess of the
breaker's amperage rating. (Overloading can occur because a
consumer plugs too many products into a circuit or due to the failure
of a product or component connected to that circuit.) While the
Commission is concerned about the failure of these FPE breakers to
meet UL calibration requirements, the Commission is unable at this
time to link these failures to the development of a hazardous situation.
According to Reliance, failure of these FPE breakers to
comply with certain UL calibration requirements do not create a
hazard in the household environment. It is Reliance's position
that FPE breakers will trip reliably at most overload levels unless
the breakers have been operated in a repetitive, abusive manner
that should not occur during residential use. Reliance maintains
that, at those few overload levels where FPE breakers may fail to
trip under realistic use conditions, currents will be too low to
generate hazardous temperatures in household wiring. Reliance
believes that its position in this regard is supported by test data that
is provided to the Commission.
The Commission staff believes that it currently has insufficient
data to accept or refute Reliance's position.
The Commission staff estimates that it would cost several
million dollars to gather the data necessary to assess fully whether
those circuit breakers which are installed in homes but which may
fail UL calibration tests present a risk to the public. Based on
the Commission's limited budget ($34 million for fiscal year 1983),
the known hazards the Commission has identified and must address
(involving products of other manufacturers) and the uncertainty of
the results of such a costly investigation, the Commission has
decided not to commit further resources to its investigation of
FPE's circuit breakers. However, despite its decision to close
this particular investigation, the Commission will continue its
investigation of circuit breakers generally. The Commission can
reopen its investigation of FPE breakers if further information
warrants.
The Commission advises consumers to take certain safety
precautions with all circuit breakers and fuses. Consumers should:
-Know your electrical circuit. Know which outlets and products
are connected to each circuit.
-Never overload any electrical circuit by connecting too
many products to the circuit. Be particularly careful not
to connect several products that demand high current (such
as heating appliances) to a low amperage circuit.
-Comply with local building codes in wiring or adding electrical
circuits. Make sure the wiring and devices used in the
circuit are connected to a circuit breaker or fuse of the
-Immediately disconnect any electrical product if problems develop.
Have the product examined by a competent repair person.
-Investigate to determine why a fuse blows or circuit breaker
trips. Do not simply replace the fuse or reset the breaker.
If a fuse blows or breaker trips, it is often a warning that
the circuit is overloaded. Check the circuit for causes of
overloading (for example, too many appliances plugged in, a
malfunctioning product, a short circuit). When in doubt,
consult a licensed electrician.
Consumers who have questions concerning circuit breakers, or
who wish to report information relating to their safety, may call
the U.S. Consumer Product Safety Commission's toll-free safety
hotline at 800-638-CPSC, teletypewriter for the hearing impaired
at 800-638-8270 (Maryland only 800-492-8104).
...
Technical Reviewers & References
|
|
Search InspectAPedia
|
- Daniel Friedman - principal author/editor of the InspectAPedia® Website
- InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also include a list of recommended books for the specific article topic as well as other references, and information sources.
- Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
- Additional technical contributors & reference sources for this article are listed below.
Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.
ELECTRICAL INSPECTION, DIAGNOSIS, REPAIR
FPE Stab-Lok HAZARDS & REPAIRS WEBSITE
SUMMARY OF the FPE Stab-Lok PROBLEM
FPE HAZARD ARTICLES, STUDIES
FPE Stab-Lok TECHNICAL REPORT
HOW TO IDENTIFY FPE & FP
REPORTS OF FPE FAILURES
HOW TO REPORT FPE INCIDENTS
FPE REPAIR ELECTRICIANS
FPE REPLACEMENT BREAKERS
FPE REPLACEMENT PANELS
FPE REPLACEMENT PANEL COSTS
CANADIAN VERSIONS of FPE Stab-Lok
FPE Stab-lok: FIRES WAITING TO HAPPEN
ADVICE TO HOME BUYERS w/ FPE PANELS
HOME INSPECTION LANGUAGE for FPE Stab-Lok
IAEI LETTER
- Note: as we didn't add this reviewers list until 2007, this list of technical reviewers is incomplete; we have received comments and suggestions regarding this topic, edits and remarks included, from engineers and management from the US CPSC, electricians (many listed at our page on field reports of FPE failures), home inspectors, licensed electricians, and electrical engineers, and even a few attorneys and real estate agents, since 1986. Technical review, critique, content suggestions, questions, or clarifications are invited and where a contributor wishes, credit and links will be provided to that source. Contact us to provide feedback.
- Dr. Jess Aronstein, electrical engineer, Poughkeepsie, NY, forensic engineering services, independent laboratory testing for various agencies
- Alan Carson, Carson Dunlop, Associates, Toronto, Ontario. Mr. Carson is a home inspection professional, educator, researcher, writer, and a principal of Carson Dunlop Associates, a Toronto home inspection and education firm. Mr. Carson is a past president of ASHI, the American Society of Home Inspectors
- Mark Cramer Inspection Services Mark Cramer, Tampa Florida, Mr. Cramer is a past president of ASHI, the American Society of Home Inspectors and is a Florida home inspector and home inspection educator. (727) 595-4211 mark@BestTampaInspector.com 11/06
- Carl Grasso, Esq., Herzfeld & Rubin, New York, NY. Mr. Grasso is an attorney who managed a plaintiff's class action litigation against Federal Pacific Electric in New Jersey.
- William King, US CPSC Director of Electrical Engineering (Ret).
- Licensed Electricians: FPE Fire and Failure Reports includes electricians who have provided cases and photographs of field failures of FPE equipment at this website.
- Homeowners, Home Inspectors, Electricians: Federal Pacific Electric (FPE) Panel Fires and other Failures includes anecdotal field reports provided by a range of contributors including electricians (and some home owners or home inspectors) who have provided cases and photographs of field failures of FPE equipment at this website.
|