FPE Stab-Lok Panel Test Report
FPE Panel Test Performed
FPE Panel Test Results
Photos of FPE Stab-Lok Panel
More Information about FPE Issues
More Information

Mobile Phone/PDA website viewMobile View
InspectAPedia Home & Site Map
Air Conditioning
InspectAPedia Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Bias Pledge
Contact Us


Federal Pacific Electric Stab Lok FPE breaker panel after testing Federal Pacific Electric Panel Tests Indicate Failures
FPEaPedia ©

Google
 
October 15, 2000, Poughkeepsie, NY. Tests by an independent forensic engineer confirmed failures of circuit breakers in a Federal Pacific Stab-Lok residential electric panel that was contributed by a homeowner. © Copyright 2008 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use the links at page left to navigate this document or to go to Other Website Topics. Green links at left show where you are in our document & website.

  • Results of Tests performed on a Homeowner's Federal Pacific Electric FPE Breaker Panel

Federal Pacific Electric Test Performed on Homeowner's FPE Breaker Panel

The breakers in this Federal Pacific Stab-Lok panel were tested according to the Underwriters Laboratories UL Standard UL 489 calibration test. This test, a subset of the entire UL 489 Standard, is intended to determine proper electrical circuit breaker function in response to overcurrent. 40-Amp breakers were tested at 135% of rated load and should trip within an hour. 20-Amp and 15-Amp breakers were tested at 200% of rated load and should trip within 2 minutes.

Federal Pacific Electric (FPE Panel) Test Results

Our site offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at inspect-ny.com/appointment.htm.

The panel contains 19 circuit breakers.

  • 4 breakers (green tabs in various photos) performed properly: the breaker opened the circuit within the prescribed time and the toggle switch moved to the "tripped" position.
  • 13 breakers (yellow tabs in various photos) did not work properly, demonstrating mechanical irregularities within the product: while all "opened" the circuit, some moved to the full-off position and others stayed in the full-on position.
  • 2 breakers (red tabs in various photos), nominally "tripped" in that there was partial or full toggle movement. However, they failed to open the circuit on at least one pole.

10% (2 out of 19) of the Federal Pacific Electric stab-lok breakers in the panel tested failed to perform properly. In the electrical industry, the failure rate for non-trip breakers is virtually zero.

Photographs of Federal Pacific Electric Panel Tested

More expert information on this topic



More Information

InspectAPedia TM Home & Site Map
Air Conditioning
InspectAPedia Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Bias Pledge
Contact Us

More Information on FPE Federal Pacific Electric Panels and Circuit Breaker Failures and Hazards

goto InspectAPedia.com - authoritative, in-depth Building Diagnostic and Repair Information for building buyers, owners, inspectorsInspectAPedia TM Home & Site Map - Building Inspection, Diagnosis, & Repair, Environmental Inspection & Testing - Research Website

GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminantsThe Mold Information Center: What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems

GO TO MOLD TEST KITS: This expert-recommended mold test kit is cheap and yet top performing *IF* you use a competent analysis laboratory!Use this simple, economical mold test kit by following our instructions on how to collect and mail mold samples to our lab

GO TO IAQ/MOLD-TEST LAB SERVICES: Mold, Pollen, indoor air quality, field and laboratory services by an expert.Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.

GO TO our PRE PURCHASE BUILDING INSPECTION SERVICES: Authoritative information for home buyers and home owners is included with your inspection.Home Inspection Construction Consulting Services & advice for home buyers

CONTACT Daniel Friedman - Dan is a senior ASHI home inspector, nationally recognized expert on building inspection, building failures, and sick building investigationContact Daniel Friedman for website content suggestions or for fee-paid consulting

Google
 
Advertise on This Website →

03/11/2008 - 10/16/00 Fileid: www.inspect-ny.com/fpe/fpetest.htm -- © 2008- 2000 Daniel Friedman, all rights reserved