Mobile View
HEATING SYSTEMS
ANTI SCALD VALVES
BOILERS, HEATING
BOILER OPERATION DETAILS
BOILER CONTROLS & SWITCHES
Air Bleeder Valves
Aquastat Functions
BOILER LEAKS CORROSION STAINS
BOILER OPERATING PROBLEMS
BOILER PARTS LIST
Cad Cell Relay Switch Flame Sensors
Circulator Pumps & Relays
Expansion Tanks
Limit Switches, Boilers
Low Water Cutoff Valves, Boilers
Mixing Valves
Relief Valves - TP Valves
Spill Switches
Stack Relay Switch
WATER HEATERS
ZONE VALVES
CARBON MONOXIDE/DIOXIDE
CARBON MONOXIDE WARNING
CHIMNEY INSPECTION DIAGNOSIS REPAIR
CHIMNEYS & Flues - Asbestos Transite Pipe
DRAFT HOODS - gas fired
DRAFT REGULATORS - barometric dampers
DUCT SYSTEMS
DUCT INSULATION, Asbestos Paper
DUCTS, Asbestos Transite Pipe
DUST FROM HVAC?
ELECTRIC HEAT
ELECTRICAL POWER SWITCH FOR HEAT
FLUE VENT CONNECTORS
FREEZE-PROOF A BUILDING
FURNACES, HEATING
DUCT SYSTEM DEFECTS
FAN LIMIT SWITCH
FURNACE CONTROLS & SWITCHES
FURNACE OPERATION DETAILS
HEAT EXCHANGER LEAKS
STACK RELAY SWITCHES
GAS PIPING, VALVES, CONTROLS
GAUGES ON HEATING EQUIPMENT
HEAT LOSS INDICATORS
HEATING COST SAVINGS METHODS
HEATING LOSS DIAGNOSIS-BOILERS
HEATING LOSS DIAGNOSIS-FURNACES
HEATING OIL CLOUD WAX GEL POINT
HEATING OIL SLUDGE
HEATING SYSTEM INSPECTION DIAGNOSIS REPAIR
HEATING INSPECTION CONCEPTS
HEATING INSPECTION PROCEDURE
HOT WATER HEATERS
HOT WATER IMPROVEMENT INSULATION
MIXING VALVES
NO HEAT - BOILER / FURNACE DIAGNOSIS
OIL BURNERS
OIL BURNER NOISE SMOKE ODORS
OIL FUEL TYPES & CHARACTERISTICS
OIL TANK GAUGES
OIL TANK LEAKS
OIL TANK SLUDGE
OIL TANKS, BURIED
PLASTIC HEATER VENT
RADIANT HEAT Floor Mistakes to Avoid
RELIEF VALVES - TP Valves
Safety Recalls
BLUERAY Recall
CHIMNEYS & Flues - Asbestos Transite
Goodman HTPV RECALL
Heat Recovery Ventilator RECALL
Lennox WARNING
Weil McLain RECALL
SAFETY DURING HEATING INSPECTION
SPILL SWITCHES - Flue Gas Detection
STAIN DIAGNOSIS on Indoor Surfaces STEAM HEATING SYSTEMS
Cad Cell Relay Switch Flame Sensors
Low Water Cutoff Valves, Boilers
Mixing Valves
Relief Valves - TP Valves
Sight Glass, Steam Boiler
Pressure Switch, Steam Boiler
Spill Switches
Stack Relay Switch
Steam Vents
LOW WATER CUTOFF CONTROLS
Water Feeder Valves, Steam
TANKLESS COILS
Tankless Coil Leaks
THERMAL TRACKING
THERMOSTATS
Transite Pipe Chimneys & Flues
WATER HEATERS
ZONE VALVES
More Information
InspectAPedia ® Home & Site Map
Air Conditioning
InspectAPedia Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Bias Pledge
Contact Us
|
 Guide to Heating Boiler Expansion Tanks
HeatAPedia ©
- Heating System Boiler Expansion Tanks, Waterlogged tanks, How to Drain an Expansion Tank - Troubleshooting & Repair Guide
- How to identify, inspect, install, repair, or service heating boiler expansion tanks
- How to inspect & repair central heating systems
- Cleaning & maintenance guide for heating systems
Our site offers impartial, unbiased advice without conflicts of interest.
We will block advertisements which we discover or readers inform us are associated with bad business practices,
false-advertising, or junk science. Our contact info is at
inspect-ny.com/appointment.htm.
Here we discuss Heating System Boiler Expansion Tanks, Waterlogged tanks, How to Drain an Expansion Tank and we
provide a heating system expsansion tan k Troubleshooting & Repair Guide.
This website answers most questions about Heating System Boiler Controls on central heating systems to aid in troubleshooting, inspection, diagnosis, and repairs.
The photo at page top shows a modern Extrol(R) bladder-type heating system expansion tank.
Contact us to suggest text changes and additions and, if you wish, to receive online listing and credit for that contribution.
© Copyright 2008 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.
Heating Boiler Expansion Tanks
Heating boiler expansion tanks are installed to absorb the initial pressure that occurs when the heating system warms up. Air molecules entrained in water
inside the heatin boiler itself as well as in the heating system piping, baseboards, or radiators, expands and thus cause an initial
pressure increase in the heating system.
If we do not provide some way to absorb this initial pressure increase, it is possible that the heating system's internal pressure would exceed
30 psi - the typical point at which a heating boiler pressure/temperature relief valve will open to spill excess pressure. If the relief
valve is forced open in this manner the heating system will first lose water each time a heating cycle starts by heating up
the boiler.
Then the heating system will take in makeup water (through the automatic water feed valve)
each time the system cools down. The result would be recurrent loss and then inflow of water through the boiler, increasing
the risk of system corrosion as well as wasting water and possibly causing other damage or operating problems.
When the heating boiler and system are cool, the expansion tank will contain mostly air. As the heating system warms up and air
entrained in the water raises system pressure, the increased pressure forces some of the heating system water into the expansion tank, thus
permitting the tank to absorb the initial increase in system pressure.
Naturally if the heating system is not operting properly
and the boiler temperature or pressure continue to rise above acceptable levels, and since the expansion tank is a fixed volume which cannot
absorb an unlimited heating system pressure increase, eventually the relief valve should also open to spill excess pressure.
Signs of Trouble with a Heating Boiler Expansion Tank
This means that if you see dripping at the pressure/temperature relief valve on a heating boiler, one thing to check is whether or not
the expansion tank is working properly. We discuss relief valve leaks caused by expansion tank problems just below.
Expansion tanks on hot water heating systems can be divided roughly into two groups: older type bladderless heating system expansion
tanks and newer type bladder-type expansion tanks such as those sold by Extrol(R).
Some heating system expansion tanks need periodic draining
Older heating system expansion tanks such as the one shown in this photo need periodic service: because air in the expansion tank can become absorbed into the heating water
over time, eventually the expansion tank can become waterlogged.
A waterlogged heating system expansion tank will be unable to absorb
the initial heating system pressure increase - it stops working. This can lead to spillage at the boiler relief valve each time the
heating system warms up.
Spillage at the relief valve is potentially dangerous: eventually minerals in the water can clog a leaky relief valve, causing it to
stop leaking - which might look ok but this means that the relief valve has become clogged - the boiler is operating without this critical
safety device and an explosion could occur.
We can determine when the expansion tank needs drainage: if the tank is heavy (try pushing it up or tapping on it) or if the relief
valve is leaking, we probably need to drain the tank and let air return to it. Many expansion tanks use a special drain valve that permits
air to flow into the tank as water is drained out. We drain the expansion tank simply using a garden hose connected to its drain valve.
But watch out, the draining water could be hot.
|
Newer expansion tanks using an internal bladder should not need service
Newer type heating system expansion tanks that use an internal bladder keep their water and air separated. These tanks should not need
service. If a bladder-type expansion tank has become waterlogged it's because the bladder has ruptured and the tank needs repair or
replacement.
Technical Reviewers & References
Particular thanks are due to experts and also consumers who read these articles and suggest corrections, changes, and additions to
the material. Content suggestions, technical corrections and content critique are invited for any of the content at our website.
Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.
More expert information on this topic
|
HEATING SYSTEMS
HEATING SYSTEM INSPECTION DIAGNOSIS REPAIR
More Information
InspectAPedia ® Home & Site Map
Air Conditioning
InspectAPedia Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Bias Pledge
Contact Us
|
More Information on Inspecting and Repairing Heating Systems
- Carbon Dioxide Gas Toxicity
- Carbon Monoxide Gas Toxicity, exposure limits, poisoning symptoms, and inspecting buildings for CO hazards
- Dust from HVAC? An Investigation of Indoor Dust Debris Blamed on a Heating/Cooling System Reveals Carpet Dust
- Goodman Furnace High Temperature Plastic Vent HTPV safety recall US CPSC notice
- Home Heating System Should Be Checked [for proper venting and for CO Carbon Monoxide Hazards - DJF]
- Inspection Procedures for Oil-Fired Heating Systems Detailed step by step approaches for inspecting complex systems]
- Lennox Pulse Furnace Safety Inspection/Warranty Program: Carbon Monoxide Warning
- Oil Tanks - The Oil Storage Tank Information Website: Buried or Above Ground Oil Tank Inspection, Testing, Cleanup, Abandonment of Oil Tanks
- Oil Tanks Above Ground, UL Standards, guidance for home owners, buyers, and inspectors
- Plastic Heating Vent Pipe & Other Heating Safety Recall Notices
- Weil McLain Model GV Gas Boiler/gas valve CPSC recall/repair
- Domestic and Commercial Oil Burners, Charles H. Burkhardt, McGraw Hill Book Company, New York 3rd Ed 1969.
- National Fuel Gas Code (Z223.1) $16.00 and National Fuel Gas Code Handbook (Z223.2) $47.00 American Gas Association (A.G.A.), 1515 Wilson Boulevard, Arlington, VA 22209 also available from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. Fundamentals of Gas Appliance Venting and Ventilation, 1985, American Gas Association Laboratories, Engineering Services Department. American Gas Association, 1515 Wilson Boulevard, Arlington, VA 22209. Catalog #XHO585. Reprinted 1989.
- The Steam Book, 1984, Training and Education Department, Fluid Handling Division, ITT [probably out of print, possibly available from several home inspection supply companies] Fuel Oil and Oil Heat Magazine, October 1990, offers an update,
- Principles of Steam Heating, $13.25 includes postage. Fuel oil & Oil Heat Magazine, 389 Passaic Ave., Fairfield, NJ 07004.
- The Lost Art of Steam Heating, Dan Holohan, 516-579-3046 FAX
- Principles of Steam Heating, Dan Holohan, technical editor of Fuel Oil and Oil Heat magazine, 389 Passaic Ave., Fairfield, NJ 07004 ($12.+1.25 postage/handling).
- "Residential Steam Heating Systems", Instructional Technologies Institute, Inc., 145 "D" Grassy Plain St., Bethel, CT 06801 800/227-1663 [home inspection training material] 1987
- "Residential Hydronic (circulating hot water) Heating Systems", Instructional Technologies Institute, Inc., 145 "D" Grassy Plain St., Bethel, CT 06801 800/227-1663 [home inspection training material] 1987
- "Warm Air Heating Systems". Instructional Technologies Institute, Inc., 145 "D" Grassy Plain St., Bethel, CT 06801 800/227-1663 [home inspection training material] 1987
- Heating, Ventilating, and Air Conditioning Volume I, Heating Fundamentals,
- Boilers, Boiler Conversions, James E. Brumbaugh, ISBN 0-672-23389-4 (v. 1) Volume II, Oil, Gas, and Coal Burners, Controls, Ducts, Piping, Valves, James E. Brumbaugh, ISBN 0-672-23390-7 (v. 2) Volume III, Radiant Heating, Water Heaters, Ventilation, Air Conditioning, Heat Pumps, Air Cleaners, James E. Brumbaugh, ISBN 0-672-23383-5 (v. 3) or ISBN 0-672-23380-0 (set) Special Sales Director, Macmillan Publishing Co., 866 Third Ave., New York, NY 10022. Macmillan Publishing Co., NY
- Installation Guide for Residential Hydronic Heating Systems
- Installation Guide #200, The Hydronics Institute, 35 Russo Place, Berkeley Heights, NJ 07922
- The ABC's of Retention Head Oil Burners, National Association of Oil Heat Service Managers, TM 115, National Old Timers' Association of the Energy Industry, PO Box 168, Mineola, NY 11501. (Excellent tips on spotting problems on oil-fired heating equipment. Booklet.)
InspectAPedia® Home & Site Map - Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice: In-depth research & advice on diagnosing, testing, correcting, & preventing building defects & indoor environmental hazards. Unbiased information, no conflicts of interest. |

The Mold Information Center: What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
|

Use this simple, economical mold test kit by following our instructions on how to collect and mail mold samples to our lab
|
Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.
|

Building Inspection, Problem Diagnosis, Forensic Investigation & Testing, Repair Consulting |
|

Contact Daniel Friedman for website content suggestions or for fee-paid consulting
|
|