SEPTIC SYSTEMS HOME HOME BUYERSGUIDE SEPTIC SYSTEMS ONLINE BOOK SAFETY WARNINGS SEPTIC SYSTEM DESIGN BASICS PERC TESTS SEPTIC TANK SIZE SEPTIC TANK DEPTH SEPTIC TANK TEES FIELD SIZE FIELD SHAPE SEPTIC CLEARANCES SEPTIC TANK PUMPING FREQUENCY SEPTIC TANK PUMPING PROCEDURE SEPTIC PUMPING REPAIR SEPTIC TREATMENTS STEEP SLOPE DESIGNS SEPTIC DESIGN ALTERNATIVES Wastewater Treatment Levels Wastewater Dispersal Methods Master List of Septic System Types AEROBIC SEPTIC SYSTEMS ATU Tank Sizes ATU Final Treatment ATU Certifications ATU Problems ATU Failure Rates, Costs ATU Maintenance Procedures Aerobic Septic Disinfectants- Calcium Hypochlorite Aerobic Septic Disinfectants-Pool Chlorine ATU Suppliers CESSPOOLS DRYWELLS EVAPORATION-TRANSPIRATION GRAVELLESS SYSTEMS LAGOON SYSTEMS PRESSURE DOSING SYSTEMS MEDIA FILTER SYSTEMS SEPTIC & GREYWATER FILTERS MOUND SYSTEMS RAISED BED SYSTEMS SAND BED SYSTEMS SEWAGE TREATMENT SYSTEMS TOILET ALTERNATIVES ALTERNATIVE SEPTIC DESIGNERS ALTERNATIVE SEPTIC PRODUCTS SEPTIC INSPECTIONS FAILURE CAUSES INSPECTING TANKS DRAINFIELD FAILURES INSPECTING D-BOX SEPTIC FIELD INSPECTION SEPTIC DYE TESTS SEPTIC FAILURE SPOTS SEPTIC INSPECTION WORK SHEETS DEFINITIONS FAILURE LAWSUIT SEPTIC REFERENCES SEPTIC CONSULTANTS SEPTIC AUTHORITIES BOOKS REFS CODES More Information InspectAPedia TM Home & Site Map Air Conditioning InspectAPedia Bookstore Electrical Environment Exteriors Heating Home Inspection Insulate Ventilate Interiors Mold Inspect/Test Roofing Plumbing Water Septic Structure Accuracy & Bias Pledge Contact Us |
Post Processing or Final Treatment of Aerobic or Aeration Septic System EffluentSeptic effluent, after having been processed through the aerobic treatment unit (ATU), may require further polishing, such as by a private wetland or greenhouse system, and may also require disinfection such as by chlorination or UV light. Other common final ATU effluent treatment systems include sand bed filters, raised bed septic fields, drip irrigation systems, evaporation/transpiration effluent disposal systems, or even a conventional septic drainfield. When all of this processing has been completed, the effluent may be sufficiently sanitary to permit discharge into a nearby body of water or directly onto the ground surface. In other circumstances the effluent is discharged into a subsurface system such as a drainfield. In this last case, the drainfield or soil absorption system will not need to meet the same treatment requirements as a conventional septic drain field, because of the pre-processing and sanitizing that have already taken place. Aerobic or aeration septic systems should have a second settlement chamber at or past the septic tankBecause the treatment tank is continually agitated the level of suspended solids remains high. Therefore an aerobic treatment unit will also include a second settling chamber to make sure that solids are not being sent out to the soil absorption system. Some designs may include a filter at the tank outlet for added protection of the absorption system. Sludge from the settling chamber is returned to the primary tank for further treatment. Chlorine or Calcium Hypochlorite Disinfection for Aerobic or Aeration Septic SystemsDisinfection methods for treated effluent include chlorination or UV light treatment. Where chlorine tablets are used it is essential that the proper type of tablets are placed into the system (see the two links below about chlorine tablets, swimming pool chlorine tablets, and calcium hypochlorite tablets (the proper stuff to use). OPINION DF: Although they may be approved for this application, I have never been completely confident in UV-light disinfection systems for several reasons:
More Reading on Disinfection Tablets for Aerobic or Aeration Septic Systems:
Use links at the left of each page (or just below) to navigate this document or to view other topics at this website. Green links show where you are in our document or website.
More expert information on this topic | |
|
SEPTIC SYSTEMS HOME HOME BUYERSGUIDE SEPTIC SYSTEMS ONLINE BOOK SAFETY WARNINGS SEPTIC SYSTEM DESIGN BASICS PERC TESTS SEPTIC TANK SIZE SEPTIC TANK DEPTH SEPTIC TANK TEES FIELD SIZE FIELD SHAPE SEPTIC CLEARANCES SEPTIC TANK PUMPING FREQUENCY SEPTIC TANK PUMPING PROCEDURE SEPTIC PUMPING REPAIR SEPTIC TREATMENTS STEEP SLOPE DESIGNS SEPTIC DESIGN ALTERNATIVES Wastewater Treatment Levels Wastewater Dispersal Methods Master List of Septic System Types AEROBIC SEPTIC SYSTEMS CESSPOOLS DRYWELLS EVAPORATION-TRANSPIRATION GRAVELLESS SYSTEMS LAGOON SYSTEMS PRESSURE DOSING SYSTEMS MEDIA FILTER SYSTEMS SEPTIC & GREYWATER FILTERS MOUND SYSTEMS RAISED BED SYSTEMS SAND BED SYSTEMS SEWAGE TREATMENT SYSTEMS TOILET ALTERNATIVES ALTERNATIVE SEPTIC DESIGNERS ALTERNATIVE SEPTIC PRODUCTS SEPTIC INSPECTIONS FAILURE CAUSES INSPECTING TANKS DRAINFIELD FAILURES INSPECTING D-BOX SEPTIC FIELD INSPECTION SEPTIC DYE TESTS SEPTIC FAILURE SPOTS SEPTIC INSPECTION WORK SHEETS DEFINITIONS FAILURE LAWSUIT SEPTIC REFERENCES SEPTIC CONSULTANTS SEPTIC AUTHORITIES BOOKS REFS CODES More Information InspectAPedia TM Home & Site Map Air Conditioning InspectAPedia Bookstore Electrical Environment Exteriors Heating Home Inspection Insulate Ventilate Interiors Mold Inspect/Test Roofing Plumbing Water Septic Structure Accuracy & Bias Pledge Contact Us |
More Information on Septic System Diagnosis, Maintenance, & Repair
|
04/14/2008 - 1/1/1995 www.inspect-ny.com/septic/AerobicTreatment.htm © Copyright 2008-1995 Daniel Friedman - all rights reserved