SEPTIC SYSTEMS HOME
SEPTIC SYSTEMS ONLINE BOOK
SEPTIC DYE TEST PROCEDURE
WHAT TO DO FIRST
OUTSIDE SEPTIC INSPECTION
  IMMEDIATE SEPTIC FAILURE EVIDENCE
  LOOK FOR SEPTIC COMPONENTS
  DIFFICULT SEPTIC SITES
  RECENT SEPTIC WORK
  SEPTIC SAFETY
STEP BY STEP SEPTIC TEST
  INSIDE SEPTIC TEST STEPS
  WATCH FOR INSIDE
  OUTSIDE SEPTIC TEST STEPS
  SEPTIC FAILURE SPOTS
  SPOTTING SEPTIC DYE BREAKOUTS
SEPTIC TEST VOLUMES & DYE AMOUNTS
  SEPTIC TEST WATER & DYE TABLE
  SEPTIC TEST FIXTURE FLOW RATE
  HOW TO SET THE SEPTIC TEST VOLUME
REPORTING SEPTIC TEST RESULTS
PUMP THE SEPTIC TANK
SEPTIC DYE TEST WARNINGS
More Information

InspectAPedia ® Home & Site Map
Plumbing Water Septic
Accuracy & Bias Pledge
Contact Us

LARGER VIEW of
septic dye breakout at a basement entry from a failed septic system buried below a driveway during conduct of a septic loading and dye test
- an expert can find clues and perform tests that reduce risk of a costly surprise

How to Report the Results of a Septic Loading & Dye Test
SepticAPedia ©

Google
 
  • How to report septic test results
  • Septic Test warnings and pitfalls
Our site offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at inspect-ny.com/appointment.htm.

This chapter provides details of how to report the results of a Septic Loading and Dye Test. Septic System Loading and Dye Tests often requested by certain lenders, involve flushing a special dye down a toilet or other drain combined with a known quantity of water sufficient to put a working load on the absorption system. If waste water leaks to the ground surface (an unsanitary condition indicating serious septic failure) one may find dye in that water provided the septic system is flowing at common rates.

Use of this information at other websites is prohibited; reproduction in electronic or printed form is prohibited. © Copyright 2008 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

HOW TO REPORT SEPTIC TEST RESULTS - & Test Conditions - What is the Minimum That A a Septic Test Report Include

A septic loading and dye test does not guarantee detection of all failing conditions. However it can make a meaningful reduction in the risk of an imminent costly septic failure, if the test is performed and documented properly. For a test to be meaningful, it is critical that reasonable test procedures be followed, such as described above, and that the procedures are documented.

A professional inspector is expected to provide sufficient documentation of the procedure followed and results obtained that an experienced third party could review that information and agree that the test provided was acceptable, regardless of the outcome. Finally, proper documentation at the site and during the test makes writing the septic report much easier.

The meaning and reliability of any test procedure is obscure unless the consultant records the test parameters and conditions. For example, a "dye test" was performed by an inspector who placed a single dye tablet into a washing machine drain line, followed by running 50 gallons of water at an upstairs plumbing fixture.

The lack of aggressiveness of the test, inadequate dye amount, minimal volume of water run, and failure to confirm that the fixture operated actually placed water into the septic tank all would have been more obvious to both the inspector and the client had this date been reported. Instead, the inspector wrote that he had "performed a septic dye test" and that there was "no evidence of a problem."

In an often-occurring anecdote, the morning after the new building owner moved into the home, sewage effluent had flooded the yard behind the home. When the septic contractor opened the tank it was evident that the tank was totally packed with solids. Litigation followed. This sounds like an extreme example, but it's all too common.

Essential documentation of septic loading and dye test procedure and conditions includes at least the following:

  • Administrative details: Inspector's name and contact information, client name, property address, inspection date, time, and pertinent weather conditions

  • Safety: Observations of visually obviously unsafe conditions at the property such as the presence of cesspools, bad tank covers, open pits, subsidence or collapsing equipment.

  • Test Limitations: Observations of conditions which limited the test or which added risk of the septic test having been subverted: recent application of bleach, damaged tank (low liquid levels), or reported maintenance history of the system

  • Pre Test Conditions: Observations before attempting the test: odors, wet conditions, grass color, rocky site, etc.

  • Plumbing Fixtures Operated: Location and identity of plumbing fixtures operated during the test, for placement of dye and for placement of the test volume of water into the system.

  • Septic System Components: Observation of or reported type of septic system components: tank (concrete, steel, reported size), reported absorption system type (drainfield, mound system, pump up system), presence of pumps (single vs. duplex), alarms.

  • Components not tested: such as drywells or other components which are known to be present or for which there is strong suggestion of their presence (such as graywater lines leaving building locations at points remote from or below the elevation of the main drain.)

  • Septic Test Parameters: Estimated total test volume of water used. Details may include fixture flow rates and flow duration. This information should include confirmation, or inability to confirm, that the test water entered the septic system.

  • Indications of septic system failure:
    • Presence of effluent or dye surfacing or breakout at the yard surface during and after the test.
    • Marked change in the wetness or softness of ground over the suspected leach area (as compared with that observed at the start of the test)
    • Septic odors
    • Discharge of septic effluent or graywater to the surface or to a nearby pond, lake, stream, drainage ditch, etc.

  • History: Information regarding the system history and maintenance if such were reported to the inspector by the seller or realtor or another party

  • If there was historical, visual, or test results that indicate or strongly suggest that the system is in-failure or that it is in very questionable condition, the report should include an explanation of these site observations, system history, and test results such that the client has an opportunity to understand the significance of the findings and reasonably probable need for repair.

  • Conclusions: there was or was not visual or historical evidence of the need for septic system repair or replacement. Other recommendations for maintenance or further investigation (such as tank pumping and inspection, D-box exploration, etc.)

An example field data recording sheet which includes a section on Dye Test Procedure Used (fixtures operated, total volume run, confirmation of flow into septic) and pre and post-test Observations such as and evidence of dye breakout is provided at Level 0 - Basic Septic Inspection Worksheet

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

SEPTIC SYSTEMS HOME
SEPTIC SYSTEMS ONLINE BOOK
SEPTIC DYE TEST PROCEDURE
HOW TO PERFORM A SEPTIC DYE TEST
WHAT TO DO BEFORE
OUTSIDE SEPTIC INSPECTION
  IMMEDIATE FAILURE EVIDENCE
  LOOK FOR COMPONENTS
  DIFFICULT SEPTIC SITES
  RECENT SEPTIC WORK
  SEPTIC SAFETY
STEP BY STEP SEPTIC TEST
  INSIDE SEPTIC TEST STEPS
  WATCH FOR INSIDE
  OUTSIDE SEPTIC TEST STEPS
  SEPTIC FAILURE SPOTS
  SPOTTING SEPTIC BREAKOUTS
SEPTIC TEST VOLUMES & DYE AMOUNTS
  SEPTIC TEST WATER & DYE TABLE
  SEPTIC TEST FIXTURE FLOW RATE
  HOW TO SET THE SEPTIC TEST VOLUME
REPORTING SEPTIC TEST RESULTS
PUMP THE SEPTIC TANK
SEPTIC DYE TEST WARNINGS

Technical Reviewers & References

Particular thanks are due to experts and also consumers who read these articles and suggest corrections, changes, and additions to the material. Content suggestions, technical corrections and content critique are invited for any of the content at our website.

  • Daniel Friedman - principal author/editor of the InspectAPedia © Website
  • Thanks to Alan Carson and Bob Dunlop, Carson Dunlop, Associates, Toronto, for permission to use illustrations from their publication, The Illustrated Home which illustrates construction details and building components. Carson Dunlop provides home inspection education, publications, report writing materials, and home inspection services. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
  • Critique, contributions wanted: Contact Us to suggest text changes and additions and, if you wish, to receive online listing and credit for that contribution

 

 

SEPTIC SYSTEMS HOME
SEPTIC SYSTEMS ONLINE BOOK

SEPTIC DYE TEST PROCEDURE
HOW TO PERFORM A SEPTIC DYE TEST
WHAT TO DO FIRST
OUTSIDE SEPTIC INSPECTION
STEP BY STEP SEPTIC TEST
SEPTIC TEST VOLUMES & DYE AMOUNTS
REPORTING SEPTIC TEST RESULTS
PUMP THE SEPTIC TANK
SEPTIC DYE TEST WARNINGS
More Information

Accuracy & Bias Pledge
Air Conditioning
InspectAPedia Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Roofing
Plumbing Water Septic
Structure
InspectAPedia ® Home & Site Map
Contact Us

More Information About Septic Systems - Onsite Waste Disposal Design, Maintenance, Repair

goto InspectAPedia.com - authoritative, in-depth Building Diagnostic and Repair Information for building buyers, owners, inspectorsInspectAPedia® Home & Site Map - Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice: In-depth research & advice on diagnosing, testing, correcting, & preventing building defects & indoor environmental hazards. Unbiased information, no conflicts of interest.
GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminants
The Mold Information Center:
What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
GO TO MOLD TEST KITS: This expert-recommended mold test kit is cheap and yet top performing *IF* you use a competent analysis laboratory!
Use this simple, economical mold test kit
by following our instructions on how to collect and mail mold samples to our lab
GO TO IAQ/MOLD-TEST LAB SERVICES: Mold, Pollen, indoor air quality, field and laboratory services by an expert.Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.
GO TO our PRE PURCHASE BUILDING INSPECTION SERVICES: Authoritative information for home buyers and home owners is included with your inspection.
Building Inspection, Problem Diagnosis
, Forensic Investigation & Testing, Repair Consulting

CONTACT Daniel Friedman - Dan is a senior ASHI home inspector, nationally recognized expert on building inspection, building failures, and sick building investigation
Contact Daniel Friedman for website content suggestions or for fee-paid consulting

Google
 

07/02/2008 - 07/03/95. -- InspectAPedia.com/septic/Septic_Test_Report.htm © Copyright 2008 -1995 Web page design & content by Daniel Friedman, all rights reserved