SEPTIC SYSTEMS HOME
SEPTIC SYSTEMS ONLINE BOOK
SEPTIC SYSTEM DESIGN BASICS
Septic Soil PERC TESTS
WHAT ARE PERC TESTS
PERC HOLE SPECIFICATIONS
PERC STANDARDS
SEPTIC TANK SIZE
SEPTIC TANK DEPTH
SEPTIC TANK TEES
FIELD SIZE
FIELD SHAPE
SEPTIC CLEARANCES
SEPTIC TANK PUMPING FREQUENCY
SEPTIC TANK PUMPING PROCEDURE
SEPTIC PUMPING REPAIR
SEPTIC TREATMENTS
STEEP SLOPE DESIGNS
DESIGN ALTERNATIVES
More Information
InspectAPedia® Home & Site Map
Air Conditioning
InspectAPedia Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Bias Pledge
Contact Us
|
Perc Test Hole Specifications for Soil Percolation Tests for Septic Field Design SepticAPedia ©
- What are the specifications for soil perc test holes: how deep, what size, etc.
- What are "perc tests" or soil percolation tests?
- How do we perform a soil perc test when designing or testing a septic system?
- Specifications and guidelines for soil percolation testing
Our site offers impartial, unbiased advice without conflicts of interest.
We will block advertisements which we discover or readers inform us are associated with bad business practices,
false-advertising, or junk science. Our contact info is at
inspect-ny.com/appointment.htm.
This chapter discusses the specifications for soil percolation holes used for testing for septic system absorption system or drainfield design. Perc tests may also be performed in order to evaluate soils when a septic system is believed to have failed,
and when repair or septic field replacement are being considered.
Readers should also see our example of state-regulated soil percolation tests at the New York State Septic System Design Regulations 75-A.4 - Soil and site evaluation for septic system design page.
Citation of this article by reference to this website and brief quotation for the sole purpose of review are permitted. Use of this information at other websites, in books or pamphlets for sale is reserved
to the author. Technical review by industry experts has been performed and is ongoing - reviewers welcomed and are listed at "References." This document is a chapter of Inspecting, Testing, & Maintaining Residential Septic Systems an online book on septic systems.
© Copyright 2008 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.
Specifications for Digging Holes for Soil Pecolation Tests for Septic System Design and Approval
How to Dig a Soil Test Pit
- Soil Perc Test Hole Depth: A typical soil perc test hole or pit is dug five feet (5') deep. On occasions a 6' hole is used if the engineer so requires.
- Perc Test Shape: The bottom of the pit should be level and about 2 ft. x 4 ft. in size. At least one side should be sloped so that if someone falls into the pit they can easily exit. (See more safety notes below).
- Perc Test and Water or Rock: If the excavator encounters water or bedrock the excavation will normally stop at that depth regardless.
- Soil Perc Test SAFETY:
- In dry soils, for safety and ease of access (to be able to climb in and out of the hole, one side
of the hole must be sloped to permit someone to easily enter and leave the pit. The other side(s) of
the hole are roughly vertical.
- In wet soils, for safety and ease of access in and out of the hole, one side of the pit must be dug
stair-stepped with each step no greater than 2 ft. in height.
- Soil Percolation Test SAFETY: Earth which has been removed to create the hole must be piled at least 2' away from the hole edges, again
for safety.
- [DF opinion]: SAFETY: engineers or workers should not enter a soil test pit (nor any other excavation) while working
alone.
- Re-fill the test holes after testing has been completed.
[Oregon's State DEQ has some nice sketches of a soil test pit at http://www.deq.state.or.us/wq/wqfact/testpits.pdf. These
notes paraphrase the Oregon DEQ's text except for [DF opinion].]
Where to Dig the Soil Test Pit for Septic Systems
Usually two percolation-rate test holes are dug, 50' to 100' apart in order to evaluate the proposed septic leachfield area.
Evidence of the seasonal high water table is noted (possibly based on changes in soil color at various depths).
For safety, perc test holes must be re-filled after the test is complete. If the hole must be left open
and unattended during the test it should be barricaded to prevent anyone from falling in. Here are some
hints from Callum County, Washington:
- Dig the perc test hole downhill from the house site if possible.
- Stay away from swales and drainage ways, and areas that are seasonally wet.
- Keep 100 feet away from all wells and surface water, including irrigation ditches.
- Septic systems cannot be located on slopes in excess of 45% (24 degrees).
- It is helpful if property boundaries and the proposed house site are marked ahead of time.
What is the Soil Test Pit Showing and How Does the Percolation Test Impact Septic System Design?
"Soil percolation or perc tests are used to determine the ability of a soil
to transmit wastewater effluent through the soil profile.
The soil percolation rate is the amount of time water takes
to move through soil, measured in minutes per inch. Finer textured soils have slower percolation rates; it takes longer
for water to drain from a test hole. These soil types need larger drainfields than soils with faster percolation rates,
such as sandy soils, to handle a given amount of wastewater.
Soils with very slow percolation rates may not be suitable
for drainfields. In Nebraska [and other jurisdictions], if soils perc at a rate slower than 60 minutes per inch, consider installing a lagoon
system if the lot is at least 3 acres. Otherwise, an engineer must design a specialized [alternative
design] septic system. Soils with very fast
percolation rates, less than 5 minutes per inch, must be modified by adding a loamy sand liner to the drainfield,
so that proper treatment can occur." [Univ. of Nebraska, Lincoln Extension, Institute of Agricultural & Natural Resources, "Residential Onsite Wastewater
Treatment: Site Evaluation]
Continue reading about soil perc tests at: PERC STANDARDS
Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website. |
SEPTIC SYSTEMS HOME
SEPTIC INFO ARTICLES
HOME BUYERSGUIDE
SEPTIC SYSTEMS ONLINE BOOK
INTRODUCTION
SAFETY WARNINGS
SEPTIC SYSTEM DESIGN BASICS
PERC TESTS
SEPTIC TANK SIZE
SEPTIC TANK DEPTH
SEPTIC TANK TEES
FIELD SIZE
FIELD SHAPE
SEPTIC CLEARANCES
SEPTIC TANK PUMPING FREQUENCY
SEPTIC TANK PUMPING PROCEDURE
SEPTIC PUMPING REPAIR
SEPTIC TREATMENTS
STEEP SLOPE DESIGNS
SEPTIC DESIGN ALTERNATIVES
Wastewater Treatment Levels
Wastewater Dispersal Methods
Master List of Septic System Types
AEROBIC SYSTEMS
CESSPOOLS
DRYWELLS
EVAPORATION-TRANSPIRATION
GRAVELLESS SYSTEMS
LAGOON SYSTEMS
PRESSURE DOSING SYSTEMS
MEDIA FILTER SYSTEMS
SEPTIC & GREYWATER FILTERS
MOUND SYSTEMS
RAISED BED SYSTEMS
SAND BED SYSTEMS
SEWAGE TREATMENT SYSTEMS
TOILET ALTERNATIVES
SEPTIC INSPECTIONS
FAILURE CAUSES
INSPECTING TANKS
DRAINFIELD FAILURES
INSPECTING D-BOX
SEPTIC FIELD INSPECTION
SEPTIC DYE TESTS
SEPTIC FAILURE SPOTS
SEPTIC INSPECTION WORK SHEETS
SEPTIC DEFINITIONS
FAILURE LAWSUIT
SEPTIC REFERENCES
SEPTIC CONSULTANTS
SEPTIC AUTHORITIES
BOOKS REFS CODES
More Information
InspectAPedia ® Home & Site Map
Air Conditioning
InspectAPedia Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Roofing
Plumbing Water Septic
Structure
Accuracy & Bias Pledge
Contact Us
|
More Information on Septic System Diagnosis, Maintenance, & Repair
- The Septic System Information Website home page for this topic
- Septic Systems Inspection, Testing, & Maintenance- online textbook. Detailed how to inspect, maintain, repair information
- The Home Buyer's Guide to Septic Systems
- Septic Tank Pumping Guide: When, Why, How to pump the septic tank
- Home & Outdoor Living Water Requirements
- Septic Tank Capacity vs Usage in Daily Gallons of Wastewater Flow, calculating required septic tank size, calculating septic tank volume from size measurements
- How Big Should the Leach Field Be? - table of soil percolation rate vs. field size
- Septic System Drainfield Absorption System Biomat Formation - what leads to drain field clogging and expensive drainfield repairs
- Table of Required Septic & Well Clearances: Distances Between Septic System & Wells, Streams, Trees, etc.
Pennsylvania State Fact Sheets relating to domestic wastewater treatment systems include
- Pennsylvania State Wastewater Treatment Fact Sheet SW-161, Septic System Failure: Diagnosis and Treatment
- Pennsylvania State Wastewater Treatment Fact Sheet SW-162, The Soil Media and the Percolation Test
- Pennsylvania State Wastewater Treatment Fact Sheet SW-l64, Mound Systems for Wastewater Treatment
- Pennsylvania State Wastewater Treatment Fact Sheet SW-165, Septic Tank-Soil Absorption Systems
- Document Sources used for this web page include but are not limited to: Agricultural Fact Sheet #SW-161 "Septic Tank Pumping," by Paul D. Robillard and
Kelli S. Martin. Penn State College of Agriculture - Cooperative Extension, edited and annotated by
Dan Friedman (Thanks: to Bob Mackey for proofreading the original source material.)
InspectAPedia® Home & Site Map - Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice: In-depth research & advice on diagnosing, testing, correcting, & preventing building defects & indoor environmental hazards. Unbiased information, no conflicts of interest. |

The Mold Information Center: What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
|

Use this simple, economical mold test kit by following our instructions on how to collect and mail mold samples to our lab
|
Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.
|

Building Inspection, Problem Diagnosis, Forensic Investigation & Testing, Repair Consulting |
|

Contact Daniel Friedman for website content suggestions or for fee-paid consulting
|
|