InspectAPedia ®

Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice
InspectAPedia
Home
| Air
Conditioning
| Electrical | Environment | Exteriors | Heating | Home
Inspection
| Insulate
Ventilate
| Interiors | Mold
Inspect/Test
| Plumbing
Water
Septic
| Roofing | Structure | Contact Us
New Directory of Professionals to Inspect or Test a Building New


SEPTIC SYSTEMS HOME
SEPTIC SYSTEMS ONLINE BOOK
SEPTIC SYSTEM DESIGN BASICS
  Septic Soil PERC TESTS
  WHAT ARE PERC TESTS
  PERC HOLE SPECIFICATIONS
  PERC STANDARDS
  SEPTIC TANK SIZE
  SEPTIC TANK DEPTH
  SEPTIC TANK TEES
  FIELD SIZE
  FIELD SHAPE
  SEPTIC CLEARANCES
  SEPTIC TANK PUMPING FREQUENCY
  SEPTIC TANK PUMPING PROCEDURE
  SEPTIC PUMPING REPAIR
  SEPTIC TREATMENTS
  STEEP SLOPE DESIGNS
DESIGN ALTERNATIVES
More Information

InspectAPedia® Home & Site Map
Air Conditioning
InspectAPedia Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Bias Pledge
Contact Us


Perc Test Hole Specifications for Soil Percolation Tests for Septic Field Design
SepticAPedia ©

Google
 
  • What are the specifications for soil perc test holes: how deep, what size, etc.
  • What are "perc tests" or soil percolation tests?
  • How do we perform a soil perc test when designing or testing a septic system?
  • Specifications and guidelines for soil percolation testing
Our site offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at inspect-ny.com/appointment.htm.

This chapter discusses the specifications for soil percolation holes used for testing for septic system absorption system or drainfield design. Perc tests may also be performed in order to evaluate soils when a septic system is believed to have failed, and when repair or septic field replacement are being considered. Readers should also see our example of state-regulated soil percolation tests at the New York State Septic System Design Regulations 75-A.4 - Soil and site evaluation for septic system design page.

Citation of this article by reference to this website and brief quotation for the sole purpose of review are permitted. Use of this information at other websites, in books or pamphlets for sale is reserved to the author. Technical review by industry experts has been performed and is ongoing - reviewers welcomed and are listed at "References." This document is a chapter of Inspecting, Testing, & Maintaining Residential Septic Systems an online book on septic systems. © Copyright 2008 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

Specifications for Digging Holes for Soil Pecolation Tests for Septic System Design and Approval

How to Dig a Soil Test Pit

  • Soil Perc Test Hole Depth: A typical soil perc test hole or pit is dug five feet (5') deep. On occasions a 6' hole is used if the engineer so requires.
  • Perc Test Shape: The bottom of the pit should be level and about 2 ft. x 4 ft. in size. At least one side should be sloped so that if someone falls into the pit they can easily exit. (See more safety notes below).
  • Perc Test and Water or Rock: If the excavator encounters water or bedrock the excavation will normally stop at that depth regardless.
  • Soil Perc Test SAFETY:
    • In dry soils, for safety and ease of access (to be able to climb in and out of the hole, one side of the hole must be sloped to permit someone to easily enter and leave the pit. The other side(s) of the hole are roughly vertical.
    • In wet soils, for safety and ease of access in and out of the hole, one side of the pit must be dug stair-stepped with each step no greater than 2 ft. in height.
    • Soil Percolation Test SAFETY: Earth which has been removed to create the hole must be piled at least 2' away from the hole edges, again for safety.
    • [DF opinion]: SAFETY: engineers or workers should not enter a soil test pit (nor any other excavation) while working alone.
    • Re-fill the test holes after testing has been completed.

[Oregon's State DEQ has some nice sketches of a soil test pit at http://www.deq.state.or.us/wq/wqfact/testpits.pdf. These notes paraphrase the Oregon DEQ's text except for [DF opinion].]

Where to Dig the Soil Test Pit for Septic Systems

Usually two percolation-rate test holes are dug, 50' to 100' apart in order to evaluate the proposed septic leachfield area. Evidence of the seasonal high water table is noted (possibly based on changes in soil color at various depths). For safety, perc test holes must be re-filled after the test is complete. If the hole must be left open and unattended during the test it should be barricaded to prevent anyone from falling in. Here are some hints from Callum County, Washington:

  • Dig the perc test hole downhill from the house site if possible.
  • Stay away from swales and drainage ways, and areas that are seasonally wet.
  • Keep 100 feet away from all wells and surface water, including irrigation ditches.
  • Septic systems cannot be located on slopes in excess of 45% (24 degrees).
  • It is helpful if property boundaries and the proposed house site are marked ahead of time.

What is the Soil Test Pit Showing and How Does the Percolation Test Impact Septic System Design?

"Soil percolation or perc tests are used to determine the ability of a soil to transmit wastewater effluent through the soil profile.

The soil percolation rate is the amount of time water takes to move through soil, measured in minutes per inch. Finer textured soils have slower percolation rates; it takes longer for water to drain from a test hole. These soil types need larger drainfields than soils with faster percolation rates, such as sandy soils, to handle a given amount of wastewater.

Soils with very slow percolation rates may not be suitable for drainfields. In Nebraska [and other jurisdictions], if soils perc at a rate slower than 60 minutes per inch, consider installing a lagoon system if the lot is at least 3 acres. Otherwise, an engineer must design a specialized [alternative design] septic system. Soils with very fast percolation rates, less than 5 minutes per inch, must be modified by adding a loamy sand liner to the drainfield, so that proper treatment can occur." [Univ. of Nebraska, Lincoln Extension, Institute of Agricultural & Natural Resources, "Residential Onsite Wastewater Treatment: Site Evaluation]

Continue reading about soil perc tests at:  PERC STANDARDS

Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.


SEPTIC SYSTEMS HOME
SEPTIC INFO ARTICLES
HOME BUYERSGUIDE
SEPTIC SYSTEMS ONLINE BOOK
INTRODUCTION
SAFETY WARNINGS
SEPTIC SYSTEM DESIGN BASICS
  PERC TESTS
  SEPTIC TANK SIZE
  SEPTIC TANK DEPTH
  SEPTIC TANK TEES
  FIELD SIZE
  FIELD SHAPE
  SEPTIC CLEARANCES
  SEPTIC TANK PUMPING FREQUENCY
  SEPTIC TANK PUMPING PROCEDURE
  SEPTIC PUMPING REPAIR
  SEPTIC TREATMENTS
  STEEP SLOPE DESIGNS
SEPTIC DESIGN ALTERNATIVES
  Wastewater Treatment Levels
  Wastewater Dispersal Methods
  Master List of Septic System Types
  AEROBIC SYSTEMS
  CESSPOOLS
  DRYWELLS
  EVAPORATION-TRANSPIRATION
  GRAVELLESS SYSTEMS
  LAGOON SYSTEMS
  PRESSURE DOSING SYSTEMS
  MEDIA FILTER SYSTEMS
  SEPTIC & GREYWATER FILTERS
  MOUND SYSTEMS
  RAISED BED SYSTEMS
  SAND BED SYSTEMS
  SEWAGE TREATMENT SYSTEMS
  TOILET ALTERNATIVES
SEPTIC INSPECTIONS
  FAILURE CAUSES
  INSPECTING TANKS
  DRAINFIELD FAILURES
  INSPECTING D-BOX
  SEPTIC FIELD INSPECTION
  SEPTIC DYE TESTS
  SEPTIC FAILURE SPOTS
  SEPTIC INSPECTION WORK SHEETS
SEPTIC DEFINITIONS
FAILURE LAWSUIT
SEPTIC REFERENCES

SEPTIC CONSULTANTS
SEPTIC AUTHORITIES
BOOKS REFS CODES
More Information

InspectAPedia ® Home & Site Map
Air Conditioning
InspectAPedia Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Roofing
Plumbing Water Septic
Structure
Accuracy & Bias Pledge
Contact Us

More Information on Septic System Diagnosis, Maintenance, & Repair

goto InspectAPedia.com - authoritative, in-depth Building Diagnostic and Repair Information for building buyers, owners, inspectorsInspectAPedia® Home & Site Map - Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice: In-depth research & advice on diagnosing, testing, correcting, & preventing building defects & indoor environmental hazards. Unbiased information, no conflicts of interest.
GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminants
The Mold Information Center:
What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
GO TO MOLD TEST KITS: This expert-recommended mold test kit is cheap and yet top performing *IF* you use a competent analysis laboratory!
Use this simple, economical mold test kit
by following our instructions on how to collect and mail mold samples to our lab
GO TO IAQ/MOLD-TEST LAB SERVICES: Mold, Pollen, indoor air quality, field and laboratory services by an expert.Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.
GO TO our PRE PURCHASE BUILDING INSPECTION SERVICES: Authoritative information for home buyers and home owners is included with your inspection.
Building Inspection, Problem Diagnosis
, Forensic Investigation & Testing, Repair Consulting

CONTACT Daniel Friedman - Dan is a senior ASHI home inspector, nationally recognized expert on building inspection, building failures, and sick building investigation
Contact Daniel Friedman for website content suggestions or for fee-paid consulting

Google
 

03/31/2008 - 1/1/1995 InspectAPedia.com/septic/Soil_Perc_Test_2.htm © Copyright 2008-1995 Daniel Friedman - all rights reserved