IAQ Mold Lab SOP More Information InspectAPedia TM Home & Site Map Air Conditioning InspectAPedia Bookstore Electrical Environment Exteriors Heating Home Inspection Insulate Ventilate Interiors Mold Inspect/Test Plumbing Water Septic Roofing Structure Accuracy & Bias Pledge Contact Us |
American Home Service IAQ Investigation Field Equipment Specifications & SOPs
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Sampling Device |
Trace length |
Nom. Trace™ Width |
Flow Rate in LPM |
Pump timer |
Calibrated |
|
Sampling Cassettes™ used with IAQ Sampling Pumps™™™ (Microscope slides, adhesive tape, and other collection media are also used) |
|||||
|
Air-O-Cell™ disposable cassette (Zefon) |
14.4mm |
1.1mm |
15 |
2-10 min. typical |
See indiv. Pump device d50=2.6u |
|
Allergenco D™ disposable
cassette ( |
14.0mm nominal |
1.1 mm nominal |
15 lpm recommended, (operates at 5-20 lpm) |
1-10 min. typical |
d50=1.7u |
|
Cyclex-D™ disposable cassette |
Round media |
|
20 lpm |
2-10 min typical |
d50=0.8u |
|
Micro 5™ disposable cassette |
Round media |
|
5 lpm |
5 min. typical |
1" tube if using Gilair-5 pump d50=0.8u |
|
25mm MCE filter cassette |
25mm MCE filter |
Filter area |
Various |
|
0.45u (F25045) |
|
37mm MCE filter cassette |
37mm MCE Filter |
Filter area |
various |
|
0.8u (F37080) |
|
Bi-Air™ disposable cassette |
Dual trace 25mm MCE filter |
Trace area |
3.5 lpm, ™™ |
10 min grab, 2-4-hr. TWA sample |
|
|
Adhesive tape-clear ™" |
Surface particle sampling mold or settled dust/debris Scotch™ Gloss Finish Multi Task Tape 34-8507-5365-7 |
||||
|
Sterile swab |
Culture collection |
||||
|
IAQ Air Sampling Pumps and Particle Collection Equipment |
|||||
|
Allergenco Mk3™ time lapse slit-impaction sampler |
14.5mm, up to 12 traces/slide |
1.1mm |
15 nom. lpm |
1min to 24-hrs™ multi-trace |
5/17/01 MK2 d50=0.67 |
|
Burkard PAS#1 |
14.0mm |
2.0mm |
10 lpm |
0-9 min |
Factory d50=2.52u |
|
Burkard PAS#2 |
14.0mm |
2.0mm |
10 lpm |
0-9min |
Factory |
|
Intermatic (used with EMS Megalite below) |
NA |
NA |
NA |
1 second to |
Factory |
|
|
NA |
NA |
3-30 lpm |
Separate duplex timed receptacle |
Factory, pump-mounted rotameter, Lab bubble tube 10/10/05 0 lab |
|
Gil-Air-5-RC pump |
NA |
NA |
1-5 adjustable |
1 min to 8-hrs |
1/15/04 Lab, Zefon bubble tube (ZBT) + (OD) in field at each use |
|
RadioShack Pump |
NA |
NA |
10 lpm |
Manual on-off |
Lab 10/10/2003™ -9/5/2005 (ZBT) in lab & (ZR) in field at each use |
|
Notes: particle collection efficiency d50 for other common devices: (J. Tucker) AGI-30 liquid impinger ™ 0.31; SAS Slit-to-Agar™0.67; Cyclex impactor 1.80; RCS radial impactor 4.00, Andersen N6 hole impactor 6.61, Rotorod 10.0. |
|||||
|
Gas Detection Equipment |
|||||
|
Sensidyne Gastec pump (gas detection) |
NA |
NA |
50 or 100 cc/ ™ /full stroke |
Manual stroke, manual count indicator |
Leak test 11/16/04 8/5/2005 |
|
Draeger accuro pump (gas detection) ARUK-FO13 #1-0893171516K09 exp F013 Serial 6400000 |
NA |
NA |
100 cc/stroke |
Manual, stroke completion indicator, automatic stroke counter |
Leak test 11/16/2004 9/5/2005 |
|
RTCA Pump#1 Rotary vane vacuum |
NA |
NA |
14.28 |
11.27 min |
Lab 6/11/04™ total 160.94L |
|
RTCA Pump#2 |
NA |
NA |
Tbd |
Tbd |
Tbd |
|
Other Equipment & Specifications |
|||||
|
Tramex |
electronic moisture encounter |
||||
|
Delmhorst |
twin-point electronic resistance moisture meter |
||||
|
Exergen ™ |
Infrared scanner ™ surface temperature |
||||
|
OD = flow indicator on device (subject to lab calibration) ZR = Zefon rotameter, for field use, verified using ZBT in lab ZBT = Zefon bubble tube (precise), multiple timed events to measure actual LPM Factory = original calibration provided by factory or independent consultant to factory. |
|||||
This document supports our General Lab Procedures and Particle
Trace Count Procedures.
See www.inspect-ny.com/sickhouse/TraceCalcs.htm
InspectAPedia TM Home & Site Map - Building Inspection, Diagnosis, & Repair, Environmental Inspection & Testing - Research Website
The Mold Information Center: What to Do About Mold in Buildings, When and How
to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
Home Inspection Construction Consulting Services & advice for home buyers
Use this simple, economical mold test kit by following
our instructions on how to collect and mail mold samples to our lab
Environmental
Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis,
Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing
removal of environmental and other hazards and prevention of their recurrence.
Contact Daniel Friedman for website content suggestions or for fee-paid consulting