FOUNDATION DIAGNOSIS
EARTHQUAKE DAMAGED FOUNDATIONS
FOUNDATION CONSTRUCTION TYPES
FOUNDATION INSPECTION METHODS
FAILURES by FOUNDATION TYPE & MATERIAL
Block Foundation & Wall Defects
Brick Foundation & Wall Defects
Brick Thermal Expansion Cracking
Concrete Poured Foundation Wall & Slab Defects
Concrete Pre-cast Foundation Defects
Stone Foundation Defects
Wood Foundation Defects
FAILURES by FOUNDATION MOVEMENT TYPE
BULGED vs. LEANING FOUNDATIONS
COMBINATIONS OF FOUNDATION MOVEMENT
Bulge & step cracks
Earthquake Damage to Foundations
Flood Damage to Foundations
Foundation Movement During Collapse
Other Foundation Step cracks
HORIZONTAL MOVEMENT IN FOUNDATIONS
Bulging, Leaning & Sliding Wall
Horizontal Foundation Creep
Horizontal Movement & step cracks in brick
Impact Damage to Foundations
Thermal Expansion Cracking in Brick
VERTICAL MOVEMENT IN FOUNDATIONS
Diagonal Cracks in Concrete Foundations
Diagonal Step Cracking in Masonry
Differential vs. Uniform Settlement Cracks
Leaning or Tipping Buildings
Uniform Width vs. Tapered Foundation Cracks
Vertical Cracks
FLOOD DAMAGE TO FOUNDATIONS
FOUNDATION DEFECTS OF OMISSION
FOUNDATION CRACK EVALUATION
DIAGONAL FOUNDATION CRACKS
HORIZONTAL FOUNDATION CRACKS
SHRINKAGE vs EXPANSION vs SETTLEMENT
Sinkholes & Building Damage
VERTICAL FOUNDATION CRACKS
FOUNDATION BULGE or LEAN MEASUREMENTS
FOUNDATION DAMAGE SEVERITY
FOUNDATION DAMAGE REPORTS
FOUNDATION INSPECTION STANDARDS
FOUNDATION MOVEMENT ACTIVE vs. STATIC
FOUNDATION REPAIR METHODS
Bulged foundation Repairs
Crack Repair Methods
Horizontal Movement Repairs
Shrinkage Crack Repairs
Vertical Movement Repairs
SITE FACTORS AFFECTING FOUNDATIONS
SLAB CRACK EVALUATION
Control Joint Cracks in Concrete
Freezing & Water Damage
Frost Heave/Expansive Soil Cracks in Slabs
Seal Cracks by Polyurethane Foam Injection
Seal Cracks in Concrete, How To
Settlement Cracks in Slabs
Settlement Cracks vs. Frost Heaves
Settlement Cracks vs. Shrinkage Cracks
Shrinkage Cracks in Slabs
Shrinkage Cracks Along Foundation Walls
Standards for Repair of Cracks in Floors
WATER ENTRY in BUILDINGS
SUMP PUMPS GUIDE
ADDITIONAL READING More Information
InspectAPedia ® Home & Site Map
Air Conditioning
InspectAPedia Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Roofing
Plumbing Water Septic
Structure
Accuracy & Bias Pledge
Contact Us
|
How to Detect, Diagnose, & Evaluate Vertical Foundation Settlement, Movement, Cracks, Damage
StructAPedia ©
- How to Evaluate and Diagnose Vertical Foundation Movement by Type & Location of Cracks, Bends, Leans, or Shift in Foundation Walls
- Different causes of foundation leaning, bulging, cracking
|
Our site offers impartial, unbiased advice without conflicts of interest.
We will block advertisements which we discover or readers inform us are associated with bad business practices,
false-advertising, or junk science. Our contact info is at
inspect-ny.com/appointment.htm.
This chapter of the "Foundation Crack Bible" discusses in detail How to Evaluate and Diagnose Vertical Foundation Movement - Foundation Settlement Cracks, Foundation Leans, Vertical or "up and down" Shifts in Foundation Walls.
Vertical foundation movement may be foundation settlement, frost heaves, movement caused by expansive clay soils, footing settlement,
or severe damage from earthquakes or other more sudden forces. Diagnosing the type of foundation movement and its cause are essential
in deciding on the appropriate measures to repair a damaged foundation wall and to prevent future foundation damage.
We distinguish among vertical movement, horizontal movement, leaning, tipping, bending, differential and
uniform settlement, earthquake and storm damage, and other foundation damage patterns.
Our "Foundation Crack Bible" document, of which this web page is a chapter, describes how to recognize and diagnose various types of foundation failure or damage, such as
foundation cracks, masonry foundation crack patterns, and moving, leaning, bulging, or bowing building foundation walls.
Also see FOUNDATION CRACK EVALUATION for a discussion of the diagnosis of specific crack patterns in masonry foundations, and see FOUNDATION BULGE or LEAN MEASUREMENTS which explains a simple method for
determining how much bulge or lean is present in a foundation or wall, then see FOUNDATION MOVEMENT ACTIVE vs. STATIC which helps determine if the foundation
movement is ongoing, and see FOUNDATION DAMAGE SEVERITY for a discussion
of just how much foundation movement is likely to be a concern.
To be used properly, this information must be combined with specific
on-site observations at the particular building in order to form a reliable opinion about the condition of that building's foundation. Anyone having
concern regarding the structural stability, safety, or damage of a building, foundation or other components, should consult a qualified expert.
Photographs of types of foundation cracks and other foundation damage: we have a large library of photographs which
we're in process of adding to this document. Pending completion of that work, contact the author if assistance is required.
© Copyright 2008 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.
Vertical Movement in Foundations & Walls
|

Vertical movement in foundations, in the most general cases, is caused by downwards movement of the wall or wall footings such as when a wall
footing sinks in soft soil, or by an up and down movement of the wall or wall footings such as when a wall is disturbed by frost in a freezing
climate or by expansive clay soils which expand or shrink as their water content increases or decreases.
Vertical foundation or slab movement is typically caused by the following conditions or events:
|
- Soil Characteristics: the presence of a footing at all, and footing width and thickness and reinforcement requirements may vary depending on the soil characteristics - different soils have different load bearing capacities, as shown in the sketch provided above by Carson Dunlop.
- Settlement or differential settlement of the supporting soils below the footings or foundation walls
- Frost heave (in areas of freezing climate) can push up (or in) buried foundation components
- Frost lensing (in areas of freezsing climate) can lift a foundation wall or post or pier even if the bottom of the structure is below the frost line
- Inadequate or even absent footings
Here are some classes of
vertical foundation or building wall movement which we illustrate and discuss in more detail below
Vertical Frost Pressure, Frost Heaving, & Lensing Movement of Foundations
|

- Differential foundation settlement: one portion of a building foundation or wall moves up or down separately from its neighbor. See Differential vs. Uniform Settlement Cracks. Differential settlement will damage the foundation or
wall by producing (usually vertical, possibly diagonal or stair stepped) cracks and other symptoms of wall movement.
- Vertical frost pressure on a foundation wall - Frost heaves and frost lensing also cause vertical movement of a foundation but in both "up" and "down" directions: water freezing to ice in wet soils expands, heaving a foundation footing or concrete floor slab up in freezing weather.
When the weather warms and ground thaws, the same (now damaged) structural components may move downwards again as frozen water (ice) returns to its liquid (water) state. In some conditions the upwards dislocation of a footing or concrete slab is cumulative. That is these structural components never return to their original "down" position, probably due to soil disturbance below the footing or slab. Our sketch at left shows how frost heave can cause both vertical and horizontal foundation movement. Drawing courtesy Carson Dunlop.
|
-
Frost lensing: Masonry walls, masonry columns, or even wooden posts, pilings, or piers can also be heaved upwards by frost, even when the bottom of the post is below the frost line. Lensing describes this phenomenon: wet soil adheres to the vertical surface of the masonry wall, or post or pier, sticking to it, and lifting this structural component as the soil itself heaves upwards during freezing.
A Common Source of Vertical Frost Heave - Un-heated Homes
|
In northern climates an inspector may encounter a concrete slab basement floor which is remarkably broken up from frost heaves. In the Northeastern U.S. early inthe 20th century it was common to route building downspouts carrying roof runoff into drains that passed under the basement or crawl space slab and into the sewer system.
When such houses are left un-heated (a likely condition in a period of high heating costs and slow real estate sales market), temperatures can drop sufficiently to cause heaving of the foundation or more commonly the basement floor slab.
If you see a floor which has broken in a rather straight line you might suspect that a stopped drain line under the floor or a broken drainline under the floor added water in that location, causing the more severe frost damage following the line of the buried pipe or drain. rawing courtesy Carson Dunlop.
|
Frost and soil pressure can also cause horizontal movement of the building foundation or piers, as we discuss further at HORIZONTAL MOVEMENT IN FOUNDATIONS.
Uniform Building Settlement
- Uniform building settlement: an entire building moves up or down together, causing little or no foundation cracking or damage,
though there could be important damage to mechanical connections to the building and even dangerous gas line leaks. [See below]
Non-Uniform Building Settlement - Leaning or Tipping Buildings
- Building tipping or leaning: a foundation wall, post, pier, or an entire building tips or leans out of level. While we consider this primarily a lateral or horizontal structural movement, in fact one end of a building can move substantially higher or lower than its opposite end - a vertical dislocation as well. For a detailed discussion of the diagnosis of specific crack patterns caused by wall bulging and leaning in masonry foundations, and see
FOUNDATION BULGE or LEAN MEASUREMENTS
Other Building Movement Causes & Cracks
- Earthquake or Storm Damage to Buildings: can cause complex building movement in multiple directions, as we illustrate at Foundation Movement due to Earthquake.
- Vertical shrinkage cracks in foundation walls: If a vertical crack is fairly uniform in width we pose that it was produced either by a non-sloping vertical settlement of one section
of the footing or foundation wall, or the crack was produced by shrinkage (in some wall materials like concrete) not by
vertical movement at all. We discuss the types of crack or movement patterns produced
by shrinkage, expansion, and settlement further at SHRINKAGE vs EXPANSION vs SETTLEMENT.
Differential Settlement vs. Uniform Settlement in a Foundation Wall
Differential settlement in a foundation or wall:: We use the term "differential settlement" to describe a condition in which one portion of a building foundation is moving down, (or up and down)
at a different rate or in a different amount from other portions of the foundation or wall.
Differential settlement will damage the foundation or
wall by producing (usually vertical, possibly diagonal or stair stepped) cracks and other symptoms of wall movement.
The large
foundation crack in this poured concrete wall was caused by differential settlement in a new foundation wall. All of this movement
occurred during the first 13 months after the home was built. |
|
Differential settlement in a building slab or supporting piers can produce significant and recurrent cracks in the living area
as drywall and trim are torn and dislocated during building movement.
This photograph shows a significant crack in an upper floor
interior wall which was bending as the center of this home settled downwards. The home had been built over
the site of a previous stream bed.
Its basement floor slab
and supporting piers was settling downwards at its center. There was some additional movement in some of the building
perimeter foundation walls, but the most significant settlement was at the center of the basement floor. |
Uniform settlement in a foundation or wall: Some buildings may settle so uniformly that the entire building moves down without producing cracking in the building's foundation or walls.
For example, while it has a few settlement cracks, the Empress Hotel in Victoria BC, a very large masonry structure built on pilings on
what was originally a marsh, has settled rather uniformly down over many decades, so that now visitors enter the hotel's "lobby" on what was originally
its second floor. |
Vertical Crack Patterns Caused by Vertical Foundation Wall Movement
Vertical movement between different sections of a masonry foundation wall, whether it is constructed of concrete, concrete block, brick, or stone,
tends to produce vertical cracks or a combination of vertical and step cracks through the wall, though there are definitely exceptions to this rule,
as we will point out.
|
Other vertical or near vertical cracks in poured concrete can occur in a masonry block or concrete or brick or stone foundation wall without leaning
or bulging if the entire wall is moving due to footing settlement or frost.
In this photograph notice that the cracking is occurring
at a building corner, probably at a garage door.
The footings at garages are often not buried as deeply as other portions of a home
(which has a basement much deeper below grade). There is greater risk that the builder didn't get the garage footers below the frost line
or that in addition, the un-heated garage is more vulnerable to frost damage (only in freezing climates of course). |
Uniform Width vs. Tapered Width Foundation Cracks
We like to look at variations in the width of a vertical crack to try to understand further what's happening to the foundation wall.
In general we pose that if a crack is wider at its top than its bottom, differential settlement may be allowing one section of the wall
to slope downwards away from its neighbor.
Or in less common cases, for example a footing which was placed mostly on soft fill
but which passes over a boulder, might break over the boulder and slope downwards on both sides of the boulder, producing
a crack wider at its top than its bottom.
If a vertical crack is fairly uniform in width we pose that it was produced either by a non-sloping vertical settlement of one section
of the footing or foundation wall, or the crack was produced by shrinkage (in some wall materials like concrete) not by
vertical movement at all.
|
But unfortunately this "rule" has exceptions. When a masonry wall is "shrinking" such as curing concrete (and some experts
pose also drying concrete block), it is not held uniformly in place
across its length.
The top of a poured concrete wall is generally unrestrained during the first portion of it's initial 28 days of curing, since
nothing has been built atop the wall, or even if someone has started floor framing, the floor framing system does not secure the top of the
wall against shrinkage movement.
On the other hand, the bottom of the wall is pinned (or should be) to its previously poured and cured
footing. The bottom of the newly poured concrete wall is more secured against horizontal movment along its length than its top.
This might therefore produce some vertical shrinkage cracks that are wider at top than bottom. Why don't we always see this in
concrete walls? As a concrete wall shrinks, the stresses produced in the wall are not concentrated at one single point, say the center
of the wall; rather, shrinkage cracks may appear in various locations in the wall, not just at its center. Shrinkage cracks may be
distributed rather than concentrated. However shrinkage cracks do tend to appear at local stress points in a wall such
as at discontinuities in its form caused by windows, doors, or holes left for mechanicals and pipes.
We discuss the types of crack or movement patterns produced
by shrinkage, expansion, and settlement further at
SHRINKAGE vs EXPANSION vs SETTLEMENT.
Diagonal Cracks in Poured Concrete Foundations
Concrete walls tend to display vertical cracks but settlement or frost heaving at a corner of a concrete wall can produce diagnoal
cracksor breaks in that location.
Steep diagonal cracks may also appear in concrete foundations due to unusual point loads that
exceed the compressive strength of the concrete (maybe it was weak concrete not high loading), and we've seen steep diagonal cracks
in poured concrete and other high-rise masonry buildings exposed to frost damage.
Steep diagonal shrinkage cracks: But in this photograph of a diagonal
crack in a poured concrete foundation, we are almost certainly looking at a large shrinkage crack. Notice that discontinuity in the crack pattern? |
Diagonal Step Cracking in Concrete block or Brick Walls Caused by Vertical Movement
Vertical movement in a concrete block or brick wall might appear as either vertical cracks but more often as step cracks in which the crack pattern follows the
mortar joints between the masonry units in a stair stepping pattern.
In this photograph, major vertical dislocation, foundation settlement,
has caused large step-cracking in the concrete block foundation wall. In addition to diagnosing and correcting the reason for
this settlement or foundation movement, this section of wall will probably have to be rebuilt.
Where step cracks are present, if you draw an imaginary line at right angles (orthogonal) to the diagonal formed by the stairstepped cracking,
the downwards direction of the line will generally point to the center of the point of downwards (or up and down) movement in the structure.
But unfortunately even this "rule" has exceptions. In Florida we observed a concrete block home with step cracking high in some of its walls.
The cracks were traced to settlement at the other end of the building which was responding to soil subsidence over a sinkhole.
|
|
|
FOUNDATION DIAGNOSIS
EARTHQUAKE DAMAGED FOUNDATIONS
FOUNDATION CONSTRUCTION TYPES
FOUNDATION INSPECTION METHODS
FAILURES by FOUNDATION TYPE & MATERIAL
Block Foundation & Wall Defects
Brick Foundation & Wall Defects
Brick Thermal Expansion Cracking
Concrete Poured Foundation Wall & Slab Defects
Concrete Pre-cast Foundation Defects
Stone Foundation Defects
Wood Foundation Defects
FAILURES by FOUNDATION MOVEMENT TYPE
BULGED vs. LEANING FOUNDATIONS
COMBINATIONS OF FOUNDATION MOVEMENT
Bulge & step cracks
Earthquake Damage to Foundations
Flood Damage to Foundations
Foundation Movement During Collapse
Other Foundation Step cracks
HORIZONTAL MOVEMENT IN FOUNDATIONS
Bulging, Leaning & Sliding Wall
Horizontal Foundation Creep
Horizontal Movement & step cracks in brick
Impact Damage to Foundations
Thermal Expansion Cracking in Brick
VERTICAL MOVEMENT IN FOUNDATIONS
Diagonal Cracks in Concrete Foundations
Diagonal Step Cracking in Masonry
Differential vs. Uniform Settlement Cracks
Leaning or Tipping Buildings
Uniform Width vs. Tapered Foundation Cracks
Vertical Cracks
FLOOD DAMAGE TO FOUNDATIONS
FOUNDATION DEFECTS OF OMISSION
FOUNDATION CRACK EVALUATION
DIAGONAL FOUNDATION CRACKS
HORIZONTAL FOUNDATION CRACKS
SHRINKAGE vs EXPANSION vs SETTLEMENT
Sinkholes & Building Damage
VERTICAL FOUNDATION CRACKS
FOUNDATION BULGE or LEAN MEASUREMENTS
FOUNDATION DAMAGE SEVERITY
FOUNDATION DAMAGE REPORTS
FOUNDATION INSPECTION STANDARDS
FOUNDATION MOVEMENT ACTIVE vs. STATIC
FOUNDATION REPAIR METHODS
Bulged foundation Repairs
Crack Repair Methods
Horizontal Movement Repairs
Shrinkage Crack Repairs
Vertical Movement Repairs
SITE FACTORS AFFECTING FOUNDATIONS
SLAB CRACK EVALUATION
Control Joint Cracks in Concrete
Freezing & Water Damage
Frost Heave/Expansive Soil Cracks in Slabs
Seal Cracks by Polyurethane Foam Injection
Seal Cracks in Concrete, How To
Settlement Cracks in Slabs
Settlement Cracks vs. Frost Heaves
Settlement Cracks vs. Shrinkage Cracks
Shrinkage Cracks in Slabs
Shrinkage Cracks Along Foundation Walls
Standards for Repair of Cracks in Floors
WATER ENTRY in BUILDINGS
SUMP PUMPS GUIDE
ADDITIONAL READING
More Information
InspectAPedia ® Home & Site Map
Structure
Contact Us
|
Use links at the left of each page or the links just below to navigate this document or to view other topics at this website. Green links show where you are in our document or website.
FOUNDATION DIAGNOSIS - how to inspect and diagnose foundation problems, in-depth diagnosis, and evaluation of all types of structural and non-structural cracks in residential foundations [Brick, Concrete, Masonry Block, Stone]
EARTHQUAKE DAMAGED FOUNDATIONS - examples of earthquake-damaged building foundations
FOUNDATION CONSTRUCTION TYPES - identify different foundation types, construction materials, effects of sequence of construction
FOUNDATION INSPECTION METHODS - what to look for when inspecting any building foundation
FAILURES by FOUNDATION TYPE & MATERIAL- unique failure characteristics of each foundation material
Block Foundation & Wall Defects
Brick Foundation & Wall Defects
Brick Thermal Expansion Cracking
Concrete Poured Foundation Wall & Slab Defects
Concrete Pre-cast Foundation Defects
Stone Foundation Defects
Wood Foundation Defects
FAILURES by FOUNDATION MOVEMENT TYPE -recognize & diagnose types of foundation damage by the nature of foundation movement
BULGED vs. LEANING FOUNDATIONS - distinction of foundation bulging from foundation leaning has important implications for stability
COMBINATIONS OF FOUNDATION MOVEMENT - the real world of foundation cracks and movement: often more than one force is at work
Bulge & step cracks
Earthquake Damage to Foundations
Flood Damage to Foundations
Foundation Movement During Collapse
Other Foundation Step cracks
HORIZONTAL MOVEMENT IN FOUNDATIONS - detection, causes, effects, evaluation of horizontal or lateral foundation movement; hillsides
Bulging, Leaning & Sliding Wall
Horizontal Foundation Creep
Horizontal Movement & step cracks in brick
Impact Damage to Foundations
Thermal Expansion Cracking in Brick
VERTICAL MOVEMENT IN FOUNDATIONS - detection, causes, effects, evaluation of vertical foundation movement, differential settlement
Diagonal Cracks in Concrete Foundations
Diagonal Step Cracking in Masonry
Differential vs. Uniform Settlement Cracks
Leaning or Tipping Buildings
Uniform Width vs. Tapered Foundation Cracks
Vertical Cracks
FLOOD DAMAGE TO FOUNDATIONS - examples of flood damaged foundations, flood damage case analysis: were these cracks due to flooding?
FOUNDATION DEFECTS OF OMISSION - recognize things that were left out, like footings, reinforcement, soil compaction, during foundation construction
FOUNDATION CRACK EVALUATION- recognize & diagnose types of foundation cracks, movement, damage, by the size, shape, location, pattern of cracks
DIAGONAL FOUNDATION CRACKS - causes and significance of diagonal foundation cracks, varies by foundation type & material
HORIZONTAL FOUNDATION CRACKS - causes and significance of horizontal foundation cracks, varies by foundation type & material
SHRINKAGE vs EXPANSION vs SETTLEMENT - which foundation materials shrink, which expand, & their characteristic crack patterns
Sinkholes & Building Damage - sinkhole recognition, significance, cause, underlying geology, areas where sinkholes are worst
VERTICAL FOUNDATION CRACKS - - causes and significance of vertical foundation cracks, varies by foundation type & material
FOUNDATION BULGE or LEAN MEASUREMENTS - procedure for documenting the amount of lean or bulge in a foundation or other building wall
FOUNDATION DAMAGE SEVERITY - rules of thumb for deciding how much foundation movement requires further action
FOUNDATION DAMAGE REPORTS - how to report foundation inspection results and damage
FOUNDATION INSPECTION STANDARDS - definition of scope of what a foundation inspector
FOUNDATION MOVEMENT ACTIVE vs. STATIC - determine if foundation movement was a one-time event or an ongoing problem
FOUNDATION REPAIR METHODS - catalog of methods used to repair damaged foundations and masonry building walls
Bulged foundation Repairs
Crack Repair Methods
Horizontal Movement Repairs
Shrinkage Crack Repairs
Vertical Movement Repairs
SITE FACTORS AFFECTING FOUNDATIONS - drainage, rock, soil compaction, slope or grading, bedrock, sloping bedrock, proximity to roads
SLAB CRACK EVALUATION - recognize and diagnose different types of slab or concrete floor cracks and movement
Control Joint Cracks in Concrete - what are control joints, why they are needed, what happens when they're omitted; are they structural?
Freezing & Water Damage - recognize frost and water damage to concrete slabs, distinguish from other crack types
Frost Heave/Expansive Soil Cracks in Slabs - distinguish between frost damage and expansive clay soil damage to slabs
Seal Cracks by Polyurethane Foam Injection - stop basement or crawl space leakage
Seal Cracks in Concrete, How To - products and methods used to seal or repair cracks in poured concrete walls, foundations, floors, & slabs.
Settlement Cracks in Slabs - recognize slab settlement, assess risk, assess potential impact on structure
Settlement Cracks vs. Frost Heaves - how to tell the difference between frost heaves and foundation settlement; does it matter?
Settlement Cracks vs. Shrinkage Cracks - critical identification of shrinkage cracks (non-structural) compared with foundation movement
Shrinkage Cracks in Slabs - causes, prevention, assessment of concrete slab shrinkage cracks
Shrinkage Cracks Along Foundation Walls - why do we see a gap between a poured concrete slab and its abutting foundation wall?
Standards for Repair of Cracks in Floors - when does a floor or slab crack need to be repaired? why?
WATER ENTRY in BUILDINGS
SUMP PUMPS GUIDE - how a sump pump can avoid foundation damage and reduce building water entry
ADDITIONAL READING
Technical Content Reviewers for Foundation Crack and Movement Damage Evaluation, Diagnosis, & Reporting
- Daniel Friedman - ASHI (1986-2006) - author of this website and article, building failures researcher.
- Thanks to Alan Carson and Bob Dunlop, Carson Dunlop, Associates, Toronto, for permission to use illustrations from their publication, The Illustrated Home which illustrates construction details and building components. Carson Dunlop provides home inspection education, publications, report writing materials, and home inspection services. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
- "Concrete Slab Finishes and the Use of the F-number System", Matthew Stuart, P.E., S.E., F.ASCE, online course at www.pdhonline.org/courses/s130/s130.htm
- Sal Alfano - Editor, Journal of Light Construction*
- Thanks to Alan Carson, Carson Dunlop, Associates, Toronto, for technical critique and some of the foundation inspection photographs cited in these articles
- Terry Carson - ASHI
- Mark Cramer - ASHI
- JD Grewell, ASHI
- Duncan Hannay - ASHI, P.E. *
- Bob Klewitz, M.S.C.E., P.E. - ASHI
- Ken Kruger, P.E., AIA - ASHI
- Aaron Kuertz aaronk@appliedtechnologies.com, with Applied Technologies regarding polyurethane foam sealant as other foundation crack repair product - 05/30/2007
- Bob Peterson, Magnum Piering - 800-771-7437 - FL*
- Arlene Puentes, ASHI, October Home Inspections - (845) 216-7833 - Kingston NY
- Greg Robi, Magnum Piering - 800-822-7437 - National*
- Dave Rathbun, P.E. - Geotech Engineering - 904-622-2424 FL*
- Ed Seaquist, P.E., SIE Assoc. - 301-269-1450 - National
- Dave Wickersheimer, P.E. R.A. - IL*
- *These reviewers have not returned comment 6/95
Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.
More expert information on this topic
|