FOUNDATION DIAGNOSIS
EARTHQUAKE DAMAGED FOUNDATIONS
FOUNDATION CONSTRUCTION TYPES
FOUNDATION INSPECTION METHODS
FAILURES by FOUNDATION TYPE & MATERIAL
Block Foundation & Wall Defects
Brick Foundation & Wall Defects
Brick Thermal Expansion Cracking
Concrete Poured Foundation Wall & Slab Defects
Concrete Pre-cast Foundation Defects
Stone Foundation Defects
Wood Foundation Defects
FAILURES by FOUNDATION MOVEMENT TYPE
BULGED vs. LEANING FOUNDATIONS
COMBINATIONS OF FOUNDATION MOVEMENT
Bulge & step cracks
Earthquake Damage to Foundations
Flood Damage to Foundations
Foundation Movement During Collapse
Other Foundation Step cracks
HORIZONTAL MOVEMENT IN FOUNDATIONS
Bulging, Leaning & Sliding Wall
Horizontal Foundation Creep
Horizontal Movement & step cracks in brick
Impact Damage to Foundations
Thermal Expansion Cracking in Brick
VERTICAL MOVEMENT IN FOUNDATIONS
Diagonal Cracks in Concrete Foundations
Diagonal Step Cracking in Masonry
Differential vs. Uniform Settlement Cracks
Leaning or Tipping Buildings
Uniform Width vs. Tapered Foundation Cracks
Vertical Cracks
FLOOD DAMAGE TO FOUNDATIONS
FOUNDATION DEFECTS OF OMISSION
FOUNDATION CRACK EVALUATION
DIAGONAL FOUNDATION CRACKS
HORIZONTAL FOUNDATION CRACKS
SHRINKAGE vs EXPANSION vs SETTLEMENT
Sinkholes & Building Damage
VERTICAL FOUNDATION CRACKS
FOUNDATION BULGE or LEAN MEASUREMENTS
FOUNDATION DAMAGE SEVERITY
FOUNDATION DAMAGE REPORTS
FOUNDATION INSPECTION STANDARDS
FOUNDATION MOVEMENT ACTIVE vs. STATIC
FOUNDATION REPAIR METHODS
Bulged foundation Repairs
Crack Repair Methods
Horizontal Movement Repairs
Shrinkage Crack Repairs
Vertical Movement Repairs
SITE FACTORS AFFECTING FOUNDATIONS
SLAB CRACK EVALUATION
Control Joint Cracks in Concrete
Freezing & Water Damage
Frost Heave/Expansive Soil Cracks in Slabs
Seal Cracks by Polyurethane Foam Injection
Seal Cracks in Concrete, How To
Settlement Cracks in Slabs
Settlement Cracks vs. Frost Heaves
Settlement Cracks vs. Shrinkage Cracks
Shrinkage Cracks in Slabs
Shrinkage Cracks Along Foundation Walls
Standards for Repair of Cracks in Floors
WATER ENTRY in BUILDINGS
SUMP PUMPS GUIDE
ADDITIONAL READING
More Information
InspectAPedia TM Home & Site Map
Air Conditioning
InspectAPedia Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Roofing
Plumbing Water Septic
Structure
Accuracy & Bias Pledge
Contact Us
|
Thermal Expansion Cracks in Brick Walls & Foundations
StructAPedia ©
- How to recognize, diagnose, & evaluate thermal expansion cracks in brick walls &: brick foundations
- Photographs of foundation damage patterns and types
|
Our site offers impartial, unbiased advice without conflicts of interest.
We will block advertisements which we discover or readers inform us are associated with bad business practices,
false-advertising, or junk science. Our contact info is at
inspect-ny.com/appointment.htm.
Here we discuss How to recognize, diagnose, & evaluate thermal expansion cracks in brick walls &: brick foundations
and how to distinguish between this type of cracking failures and other cracks and movement in masonry foundations or walls, such as
concrete, masonry block, brick, stone foundation
damage due to impact, settlement, frost or water damage, and other causes.
Types of foundation cracks, crack patterns, differences in the meaning of cracks in different foundation materials, site conditions, building history,
and other evidence of building movement and damage are described to
assist in recognizing foundation defects and to help the inspector separate cosmetic or low-risk conditions from
those likely to be important and potentially costly to repair.
Also see this close companion article: FOUNDATION CRACK EVALUATION which discusses in detail the process of evaluating foundation cracks and signs of foundation damage by examining the crack size, shape, pattern, and location.
© Copyright 2008 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.
How to Identify, Diagnose, & Evaluate Thermal Expansion Damage to Brick Walls
Thermal expansion failures in structural or veneer brick walls: is a topic misunderstood by many builders, masons, engineers, architects, and inspectors.
As Dave Wickersheimer, R.A. P.E. and masonry failure expert has pointed out, brick "grows" in size indefinitely [though
probably most of its size increase is early after it's manufacture.]
But a separate factor that can cause very large movements and
extensive damage to brick structures or brick veneer walls is the thermal expansion which occurs across a long or tall brick wall
when that wall is heated by sun exposure. The photographs here show significant thermal expansion damage in a long brick structure
when we first photographed
it in 1989. We visited this site again for an update in June 2007.
This brick veneer wall was built over a concrete block building.
The brick veneer was attached using normal steel strap
methods and the brick veneer was also reinforced at intervals using a horizontal steel wire. But the wall, more than 100' long, was
built without a single expansion joint.
As the south-facing wall of this building heated in summer sun the wall grew in length
until it pushed out the East and West building corners at their tops for a total of nearly 3" measured by dropping a plumb line from each building corner.
The veneer movement produced a variety of damage, including:
-
Significant breaks and gaps at vertical brick mortar joints due to thermal expansion and perhaps some frost and water damage.
|
-
Horizontal sliding breaks in brick mortar joints, exposing reinforcing wire to rust, exfoliation, and additional damage from those forces
as the exfoliating wire produced still more pressure on the mortar joint.
|
-
Step cracking following mortar joints near the building corners and where the wall movement was resisted by first story intersecting brick walls abutting at right angles the middle section of the long brick wall.
|
-
Cracks and broken bricks, and damaged windows at intersections of brick walls and these openings. Additional
window damage is shown in the color photograph lower on this page.
|
- Cracks in the interior concrete block structural wall were observed in the building interior
- Leaks and water entry and some frost damage and related loosening of the brick veneer at various locations around the building but were
most severe in areas exposed to thermal expansion of long brick veneer walls.
We were surprised that there was not more extensive damage to the structural walls themselves, and we urged the building management to consult
an experienced mason for further inspection and repair. We expected the mason to cut vertical expansion joints in the wall and to seal these
joints with an appropriate flexible filler material or gasket. No repairs were made, the cracks had grown slightly, and leaks had increased
at the time of an informal site inspection and visit we made again in June 2007, as shown in the photographs below.
Here are some factors which determine the extent of thermal expansion damage to a brick wall or structure
- Proper installation of thermal expansion joints is the critical design factor to avoid thermal expansion damage to brick.
- Selection and application of connectors between the brick veneer and the structure is an important factor - some connectors
permit more movement between the brick veneer and the structure. However even if a large brick veneer wall is properly fastened,
if lacks expansion joints damage is likely, especially on the sun-exposed walls
- Sun exposure: simply walking around a large structure such as the building complex shown in these photographs, it becomes
quite apparent that thermal expansion damage occurs worst on long brick walls which are facing South and/or those which receive
the most sun exposure.
- Means of brick veneer attachment: A second factor in
the probability of damage to a brick veneer wall is the means of attachment of the veneer to the building structure. Brick veneer walls
were traditionally secured to the underlying wood or masonry structure using corrugated steel strips which were fastened at one end
to the structure and at the other end laid in the brick veneer wall at mortar joints.
These connectors permit some vertical
movement between the structures but resists lateral movement. Some newer brick veneer connectors are designed to permit
horizontal as well as some vertical movement differences between the brick veneer wall and the structure. And of course, where
proper expansion joints are provided in the expanse of a brick wall and at windows and doors which penetrate that wall, we
should not see thermal expansion damage to the bricks nor to the structure.
- Brick veneer bottom support: on some residential properties we've found loose brick veneer walls that lacked
adequate support to carry their weight. Typical brick veneer support on a residential building uses either a steel angle
iron fastened to the foundation wall to carry the bricks from their first course, or if the brick veneer was in the
original plans for the building the architect or builder may have specified that the building foundation wall project
approximately 4" (one brick width) out from the building structural wall to carry the load of the bricks.
- Combined effects of weather & thermal cracking may increase cracking and movement in a brick structure or brick
veneer structure. It's possible that the wall-corner cracks in the photograph at the top of this page were aggravated
by leaks at the roof or roof parapet since this building is located in a freezing climate.
- Distinguishing between brick thermal cracking and frost cracking: How can we distinguish between
brick cracking due to roof or parapet wall leaks and brick cracking due to thermal movement: a leak and frost related crack
on a masonry building tends to be horizontal near the top of the building wall at about the location of the roof surface
behind the parapet wall, or just below that point - describing where water is entering the structure. Thermal cracking
in the same brick wall will generate stair-step cracks or vertical cracks near the wall ends (or building corners) and will be independent of high-on-wall
horizontal cracks that map the surface of the roof itself.
- Brick veneer vs. structural brick: OPINION: we suspect that at least in some cases, a brick veneer wall might suffer worse damage from thermal expansion than a brick structural wall,
based on the hypothesis that a
brick veneer wall, being a single brick in thickness, has less thermal mass and so will heat up more quickly across its surface than a
structural brick wall which will be two or more wythes of bricks in thickness, joined by bond courses.
|
FOUNDATION DIAGNOSIS
FOUNDATION INSPECTION METHODS
FOUNDATION CONSTRUCTION TYPES
FAILURES by FOUNDATION TYPE & MATERIAL
Poured Concrete Foundation Wall & Slab Defects
Pre-Cast Concrete Foundation Defects
Stone Foundation Defects
Brick Foundation & Wall Defects
Brick Thermal Expansion Cracking
Masonry Block Foundation & Wall Defects
Wood Foundation Defects
FAILURES by FOUNDATION MOVEMENT TYPE
VERTICAL MOVEMENT IN FOUNDATIONS
HORIZONTAL MOVEMENT IN FOUNDATIONS
COMBINATIONS OF FOUNDATION MOVEMENT
BULGED vs. LEANING FOUNDATIONS
FLOOD DAMAGE TO FOUNDATIONS
FOUNDATION DEFECTS OF OMISSION
FOUNDATION CRACK EVALUATION
DIAGONAL FOUNDATION CRACKS
HORIZONTAL FOUNDATION CRACKS
SHRINKAGE vs EXPANSION vs SETTLEMENT
Sinkholes & Building Damage
VERTICAL FOUNDATION CRACKS
FOUNDATION BULGE or LEAN MEASUREMENTS
FOUNDATION DAMAGE SEVERITY
FOUNDATION DAMAGE REPORTS
FOUNDATION INSPECTION STANDARDS
FOUNDATION MOVEMENT ACTIVE vs. STATIC
FOUNDATION REPAIR METHODS
SITE FACTORS AFFECTING FOUNDATIONS
SLAB CRACK EVALUATION
Control Joint Cracks in Concrete
Freezing & Water Damage
Frost Heave/Expansive Soil Cracks in Slabs
Seal Cracks by Polyurethane Foam Injection
Seal Cracks in Concrete, How To
Settlement Cracks in Slabs
Settlement Cracks vs. Frost Heaves
Settlement Cracks vs. Shrinkage Cracks
Shrinkage Cracks in Slabs
Shrinkage Cracks Along Foundation Walls
Standards for Repair of Cracks in Floors
WATER ENTRY in BUILDINGS
SUMP PUMPS GUIDE
ADDITIONAL READING
More Information
InspectAPedia TM Home & Site Map
Air Conditioning
InspectAPedia Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Roofing
Plumbing Water Septic
Structure
Accuracy & Bias Pledge
Contact Us
|
Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.
FOUNDATION DIAGNOSIS - how to inspect and diagnose foundation problems, in-depth diagnosis, and evaluation of all types of structural and non-structural cracks in residential foundations [Brick, Concrete, Masonry Block, Stone]
EARTHQUAKE DAMAGED FOUNDATIONS - examples of earthquake-damaged building foundations
FOUNDATION CONSTRUCTION TYPES - identify different foundation types, construction materials, effects of sequence of construction
FOUNDATION INSPECTION METHODS - what to look for when inspecting any building foundation
FAILURES by FOUNDATION TYPE & MATERIAL- unique failure characteristics of each foundation material
Block Foundation & Wall Defects
Brick Foundation & Wall Defects
Brick Thermal Expansion Cracking
Concrete Poured Foundation Wall & Slab Defects
Concrete Pre-cast Foundation Defects
Stone Foundation Defects
Wood Foundation Defects
FAILURES by FOUNDATION MOVEMENT TYPE -recognize & diagnose types of foundation damage by the nature of foundation movement
BULGED vs. LEANING FOUNDATIONS - distinction of foundation bulging from foundation leaning has important implications for stability
COMBINATIONS OF FOUNDATION MOVEMENT - the real world of foundation cracks and movement: often more than one force is at work
Bulge & step cracks
Earthquake Damage to Foundations
Flood Damage to Foundations
Foundation Movement During Collapse
Other Foundation Step cracks
HORIZONTAL MOVEMENT IN FOUNDATIONS - detection, causes, effects, evaluation of horizontal or lateral foundation movement; hillsides
Bulging, Leaning & Sliding Wall
Horizontal Foundation Creep
Horizontal Movement & step cracks in brick
Impact Damage to Foundations
Thermal Expansion Cracking in Brick
VERTICAL MOVEMENT IN FOUNDATIONS - detection, causes, effects, evaluation of vertical foundation movement, differential settlement
Diagonal Cracks in Concrete Foundations
Diagonal Step Cracking in Masonry
Differential vs. Uniform Settlement Cracks
Leaning or Tipping Buildings
Uniform Width vs. Tapered Foundation Cracks
Vertical Cracks
FLOOD DAMAGE TO FOUNDATIONS - examples of flood damaged foundations, flood damage case analysis: were these cracks due to flooding?
FOUNDATION DEFECTS OF OMISSION - recognize things that were left out, like footings, reinforcement, soil compaction, during foundation construction
FOUNDATION CRACK EVALUATION- recognize & diagnose types of foundation cracks, movement, damage, by the size, shape, location, pattern of cracks
DIAGONAL FOUNDATION CRACKS - causes and significance of diagonal foundation cracks, varies by foundation type & material
HORIZONTAL FOUNDATION CRACKS - causes and significance of horizontal foundation cracks, varies by foundation type & material
SHRINKAGE vs EXPANSION vs SETTLEMENT - which foundation materials shrink, which expand, & their characteristic crack patterns
Sinkholes & Building Damage - sinkhole recognition, significance, cause, underlying geology, areas where sinkholes are worst
VERTICAL FOUNDATION CRACKS - - causes and significance of vertical foundation cracks, varies by foundation type & material
FOUNDATION BULGE or LEAN MEASUREMENTS - procedure for documenting the amount of lean or bulge in a foundation or other building wall
FOUNDATION DAMAGE SEVERITY - rules of thumb for deciding how much foundation movement requires further action
FOUNDATION DAMAGE REPORTS - how to report foundation inspection results and damage
FOUNDATION INSPECTION STANDARDS - definition of scope of what a foundation inspector
FOUNDATION MOVEMENT ACTIVE vs. STATIC - determine if foundation movement was a one-time event or an ongoing problem
FOUNDATION REPAIR METHODS - catalog of methods used to repair damaged foundations and masonry building walls
Bulged foundation Repairs
Crack Repair Methods
Horizontal Movement Repairs
Shrinkage Crack Repairs
Vertical Movement Repairs
SITE FACTORS AFFECTING FOUNDATIONS - drainage, rock, soil compaction, slope or grading, bedrock, sloping bedrock, proximity to roads
SLAB CRACK EVALUATION - recognize and diagnose different types of slab or concrete floor cracks and movement
Control Joint Cracks in Concrete - what are control joints, why they are needed, what happens when they're omitted; are they structural?
Freezing & Water Damage - recognize frost and water damage to concrete slabs, distinguish from other crack types
Frost Heave/Expansive Soil Cracks in Slabs - distinguish between frost damage and expansive clay soil damage to slabs
Seal Cracks by Polyurethane Foam Injection - stop basement or crawl space leakage
Seal Cracks in Concrete, How To - products and methods used to seal or repair cracks in poured concrete walls, foundations, floors, & slabs.
Settlement Cracks in Slabs - recognize slab settlement, assess risk, assess potential impact on structure
Settlement Cracks vs. Frost Heaves - how to tell the difference between frost heaves and foundation settlement; does it matter?
Settlement Cracks vs. Shrinkage Cracks - critical identification of shrinkage cracks (non-structural) compared with foundation movement
Shrinkage Cracks in Slabs - causes, prevention, assessment of concrete slab shrinkage cracks
Shrinkage Cracks Along Foundation Walls - why do we see a gap between a poured concrete slab and its abutting foundation wall?
Standards for Repair of Cracks in Floors - when does a floor or slab crack need to be repaired? why?
WATER ENTRY in BUILDINGS
SUMP PUMPS GUIDE - how a sump pump can avoid foundation damage and reduce building water entry
ADDITIONAL READING
More Information
Technical Content Reviewers for Foundation Crack and Movement Damage Evaluation, Diagnosis, & Reporting
- Daniel Friedman - ASHI (1986-2006) - author of this website and article, building failures researcher.
- "Concrete Slab Finishes and the Use of the F-number System", Matthew Stuart, P.E., S.E., F.ASCE, online course at www.pdhonline.org/courses/s130/s130.htm
- Sal Alfano - Editor, Journal of Light Construction*
- Thanks to Alan Carson, Carson Dunlop, Associates, Toronto, for technical critique and some of the foundation inspection photographs cited in these articles
- Terry Carson - ASHI
- Mark Cramer - ASHI
- JD Grewell, ASHI
- Duncan Hannay - ASHI, P.E. *
- Bob Klewitz, M.S.C.E., P.E. - ASHI
- Ken Kruger, P.E., AIA - ASHI
- Aaron Kuertz aaronk@appliedtechnologies.com, with Applied Technologies regarding polyurethane foam sealant as other foundation crack repair product - 05/30/2007
- Bob Peterson, Magnum Piering - 800-771-7437 - FL*
- Arlene Puentes, ASHI, October Home Inspections - (845) 216-7833 - Kingston NY
- Greg Robi, Magnum Piering - 800-822-7437 - National*
- Dave Rathbun, P.E. - Geotech Engineering - 904-622-2424 FL*
- Ed Seaquist, P.E., SIE Assoc. - 301-269-1450 - National
- Dave Wickersheimer, P.E. R.A. - IL, professor, school of structures division, UIUC - University of Illinois at Urbana-Champaign School of Architecture. Professor Wickersheimer specializes in structural failure investigation and repair for wood and masonry construction. *
- *These reviewers have not returned comment 6/95
Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.
More expert information on this topic
|
FOUNDATION DIAGNOSIS
EARTHQUAKE DAMAGED FOUNDATIONS
FOUNDATION CONSTRUCTION TYPES
FOUNDATION INSPECTION METHODS
FAILURES by FOUNDATION TYPE & MATERIAL
FAILURES by FOUNDATION MOVEMENT TYPE
FLOOD DAMAGE TO FOUNDATIONS
FOUNDATION DEFECTS OF OMISSION
FOUNDATION CRACK EVALUATION
FOUNDATION BULGE or LEAN MEASUREMENTS
FOUNDATION DAMAGE SEVERITY
FOUNDATION DAMAGE REPORTS
FOUNDATION INSPECTION STANDARDS
FOUNDATION MOVEMENT ACTIVE vs. STATIC
FOUNDATION REPAIR METHODS
SITE FACTORS AFFECTING FOUNDATIONS
SLAB CRACK EVALUATION
WATER ENTRY in BUILDINGS
ADDITIONAL READING
More Information
InspectAPedia TM Home & Site Map
Air Conditioning
InspectAPedia Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Roofing
Plumbing Water Septic
Structure
Accuracy & Bias Pledge
Contact Us
|
More Information on Building Diagnostic Inspections and Repairs
FOUNDATION CRACK EVALUATION discusses detail the process of evaluating foundation cracks and signs of foundation damage by examining the crack size, shape, pattern, and location.
FOUNDATION BULGE or LEAN MEASUREMENTS explains a simple method for determining how much bulge or lean is present in a foundation or wall,
FOUNDATION MOVEMENT ACTIVE vs. STATIC helps determine if the foundation movement is ongoing,
FOUNDATION DAMAGE SEVERITY discusses how we decide the severity of foundation damage and the urgency of further action.
FAILURES by FOUNDATION TYPE & MATERIAL describes the types of foundation damage, cracks, leaks, or other defects associated with each type of foundation material (concrete, brick, stone, concrete block, etc.).
InspectAPedia TM Home & Site Map - Building Inspection, Diagnosis, & Repair, Environmental Inspection & Testing - Research Website
The Mold Information Center: What to Do About Mold in Buildings, When and How
to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
Home Inspection Construction Consulting Services & advice for home buyers
Contact Daniel Friedman for website content suggestions or for fee-paid consulting
|